![HomeMatic HmIPW-P-DRBL4 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/homematic/hmipw-p-drbl4/hmipw-p-drbl4_manual_2153757049.webp)
49
Restore factory settings
E11
Under-voltage
(bus voltage
too low)
Check the voltage
supply and adjust
the voltage supply in
accordance with the
number of devices
connected.
8
Restore factory settings
The factory settings of the device can be restored.
If you do this, you will lose all your settings.
To restore the factory settings of the blind actuator,
please proceed as follows:
• Press and hold down the system button
(A)
for 4
seconds until the LED
(A)
quickly starts flashing
orange (
see figure 5
).
• Release the system button again.
• Press and hold down the system button again for
4 seconds, until the LED lights up green.
• Release the system button to finish the procedure.
The device will perform a restart.