37
Hazard information
Exceeding this capacity could lead to the de-
struction of the device, fires or electric shocks.
The circuit to which the device and the load will
be connected must be protected by a circuit
breaker in accordance with EN60898-1 (tripping
characteristic B or C, max. 10 A rated current,
min. 6 kA breaking capacity, energy limitation
class 3). Installation regulations according to VDE
0100 and HD382 or 60364 must be observed.
The circuit breaker must be easily accessible to
the user and marked as the disconnecting device
for the actuator.
Before the actuator is connected, remove the
fuse from the fuse box.
Except for configuration, the device may only be
operated with an associated switch cover.
The device has not been designed to support
safety disconnection.
Devices with electronic power supply units (e.g.
TV or high voltage LED light sources) can gener-
ate inrush currents of more than 100 A. Switching
such kind of loads may lead to premature wear of