Start-up
the blinds down for the selected channel to the
corresponding terminal ( )
(E)
(
see figure 6+7
).
The phase conductor connection is marked with
an arrow pointing to the centre of the device, the
switched phase conductor with an arrow point-
ing towards outside. To connect or loosen the
conductor, the white actuation lever at the top of
the clamp has to be pressed.
The network terminals may be used only for
connecting the power supply to the device or for
connecting loads to the device. The connection
(looping through) of conductors via the network
terminals of the device to other devices is not
permitted!
• Connect the external push-buttons/switches as
shown to connecting terminal 1 to 8 (
see fig. 7
):
- Connecting terminal 1, 3, 5, 7
(E)
: “Down”
- Connecting terminal 2, 4, 6, 8
(F)
: “Up”
• Replace the cover of the power distribution panel.