Step 9 – Control Valve Set-up
During cold weather, the control valve should be warmed to room temperature before
operating. Note: All electrical connections must be done according to local codes.
Plug the control valve into a standard, grounded 120 volt (60 Hz) electrical outlet. Be certain
that the outlet is uninterrupted and not controlled by a switch. An extension cord may be
used to reach a suitable electrical outlet. Ensure that the extension cord is UL/CSA certified
and of an appropriate wire gauge for the application. Plug the other end of the power cord
into the electrical port on the control valve.
Note: The electrical port on the control valve is located
on the right side of the valve (when you are facing the
control panel), just behind the tab used to remove the
valve cover. It is a bit tricky to find.
Once plugged in, the touch screen on the control valve
will illuminate. The control valve may need to reset to
the home position when it is powered up. If it does, the
motor will run for a few seconds.
Optional: The touch screen is shipped with a protective
plastic film that can be peeled off.
The following is the primary “Home Screen” or Main Menu: