30
If your hardness level is expressed in ppm or mg/l, first divide by 17.1 to convert to hardness
expressed in grains per gallon (GPG).
Then, calculate your Iron Adjustment Factor as follows:
(iron level in ppm or mg/l + manganese level in ppm or mg/l) x 4
Your recommended feed water hardness setting is equal to:
Hardness in GPG + Iron Adjustment Factor
To adjust the hardness setting, touch “hardness” and two blue arrows will appear. Touch the
arrows on the left or right to adjust the setting.
When you are satisfied that all of the settings are correct, press the CHECKMARK ICON in the
bottom right corner of the screen. To cancel your changes and return to the home screen,
press the “X” ICON at any time.
Touch Screen Display Brightness
You can adjust the brightness of your touch screen by touching the BRIGHTNESS ICON.
The brightness can be set on a scale from 0 to 10 with 10 being the brightest. The default
setting is 10. To change the setting, touch “power,” then use the 2 blue arrows to increase or
decrease the brightness to suit your preferences. Each time you press one of the blue
arrows, the screen brightness will change accordingly.
When you are satisfied with the brightness level, press the CHECKMARK ICON in the bottom
right corner of the screen. To cancel your changes and return to the home screen, press the
“X” ICON at any time.
Master Settings
The Master Settings Mode allows service technicians to set-up the valve for optimal
performance. A password is required to enter this mode. We do not recommend that you
alter any of these settings. See Master Settings Mode below.