METER
Parameter
Setting
meter type
1.25” turbine
generic
na
plumbing leak detect
on
OPERATION DURING A POWER FAILURE
The 5810XTR2 valve/controller includes integral power backup. In the event of power failure,
the control shifts into a power-saving mode. The display and motor shut down, but it
continues to keep track of the time and day for a minimum of 48 hours.
The system configuration settings are stored in a non-volatile memory and are stored
indefinitely with or without line power. The Time of Day flashes when there has been a
power failure. Press any button to stop the Time of Day from flashing.
If power fails while the unit is in regeneration, the control will save the current valve position
before it shuts down. When power is restored, the control will resume the regeneration cycle
from the point where power failed. Note that if power fails during a regeneration cycle, the
valve will remain in its current position until power is restored.