background image

Background

The instant water heater is a novel appliance designed to supply
continuous  and unlimited hot water while conserving energy
saving up to 80% in electricity compared to a 120 liter boiler.

Up to 6kW
(One phase)

Also for 2 x 127V (2 )
for Latin America

7kW to 9.5kW
(One phase)

Also for
127V up to 5kW

7kW to 9.5kW
(Two phase)

1. Multi-pole switch
2. Terminal block
3. Thermostat
4. Microswitch

5. Switches
6. LED Light
7. Heating elements
8. Pressure switch

Optima-Platinum - 3.0

1.0;2.0 or 3.0kW

3.0    3.3    3.6

2.5mm

2

16amps

Optima-Platinum - 3.5

1.5;2.0 or 3.5kW

3.2    3.5    3.8

2.5/4mm

2

20amps

Optima-Platinum - 5.0

2.0;3.0 or 5.0kW

5.0    5.5    6.0

4/6mm

2

25amps

Optima-Platinum - 5.5

2.5;3.0 or 5.5kW

5.5    6.0    6.6

4/6mm

2

25-32amps

Optima-Platinum - 7.0

3.0;4.0 or 7.0kW

7.0    7.7    8.3

6/10mm

2

40amps

Optima-Platinum - 8.0

4.0;4.0 or 8.0kW

7.3    8.0    8.7

6/10mm

2

40amps

Optima-Platinum - 9.5

4.5;5.0 or 9.5kW

8.7    9.5    10.3

10mm

2

45amps

Model

Heat Setting

kW loading

Recommended

cable size

Recommended

fuse rating

220V 230V 240V

• 

Operating water pressure 0.3-7 BAR (5-100 psi)   

• 

Water pressure operated power switch

• 

Standard 1/2"fl compression inlet connection  

• 

Top-left and right cable entry  

• 

Bottom-left water entry

• 

Fixing pack and instructions supplied

UNIT DIMENSIONS:  HEIGHT 185mm   WIDTH 300mm   DEPTH 110mm

Table 2

S.N.1

16003D

Fig. No. 1

2 Cable entry
right and left

Terminal block
cable connector

Releave snap

to release cover

To remove triangle
Push out from inner side
of white cover
on this point

TE

MPE

RATUR

E

C ONTR OL

Multi Temp

MULTI TEMPERATURE CONTROL

Multi Shower

Shower kit

Quality Sprayer with Adju
stable Shower Head, Slidi
ng Rail and Soap Dish

ELCB 

(Optional)

Only for Platinum

TE

MPE

RATUR

E

C ONTR OL

Multi Temp

MULTI TEMPERATURE CONTROL

3

TE

M

PE

RAT

URE SE

TT

IN

G

S

Only for
Multi and
Completa models

ELCB
(Optional)

Flow control

Power setting

Flow control

Power setting

Power setting

Flow control

Power setting

Installation Instructions for "Platinum"and “Optima” model

Tri

Shower 

or

 Sink

Multi

Shower 

or

 Sink

Fig. No. 1

2 Cable entry
right and left

Terminal block
cable connector

To remove triangle
Push out from inner side
of white cover
on this point

Releave
snap to
release
cover

ELCB
(Optional)

Temp. Digital

Display

(in Digital model)

Temp. Digital

Display

(in Digital model)

Temp. Digital Display

(in Digital model)

Power

In Platinum Digital Models

Quick

Connector

Temp.

Sensor

Digital

Display

Power

In Platinum Digital Models

Quick

Connector

Temp.

Sensor

Digital

Display

Power

In Platinum Digital Models

Quick

Connector

Temp.

Sensor

Digital

Display

Quick

Connector

Quick

Connector

Quick

Connector

Tri Temp

3 TEMPERATURE SETTINGS