1
1
3
3
WIRELESS COMMUNICATIONS WITH HAI CONTROLLER
This thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy Star
program. When used with remote systems, HAI recommends that the thermostat be configured as "non-
programmable" (See Setup Item 03 - "Display Options").
HAI AUTOMATION SYSTEMS
The thermostat can communicate with an HAI automation system over a Z-Wave network. The controller can
send commands to the thermostat to change mode, cool setting, heat setting, status of fan and hold, and other
items.
ADDING A THERMOSTAT TO THE Z-WAVE NETWORK
When prompted by Z-Wave primary or inclusion controller to include the thermostat to the network, press and
release the ‘Hold’ button on the thermostat. This will include the thermostat on the Z-Wave network.
REMOVING A THERMOSTAT FROM THE Z-WAVE NETWORK
When prompted by Z-Wave primary or inclusion controller to exclude the thermostat from the network, press
and release the ‘Hold’ button on the thermostat. This will exclude the thermostat from the Z-Wave network.
The thermostat supports the following command classes:
COMMAND_CLASS_THERMOSTAT_MODE
COMMAND_CLASS_THERMOSTAT_SETPOINT
COMMAND_CLASS_THERMOSTAT_FAN_MODE
COMMAND_CLASS_THERMOSTAT_FAN_STATE
COMMAND_CLASS_THERMOSTAT¬_OPERATING_STATE
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_CLOCK
COMMAND_CLASS_THERMOSTAT_MODE
Upon power up, allow 10 seconds for the RC-90BZ thermostat to initialize. After 10 seconds, a controller can
set the mode, get the current mode, and get the modes supported by the thermostat.
COMMAND_CLASS_THERMOSTAT_SETPOINT
Upon power up, allow 10 seconds for the RC-90BZ thermostat to initialize. After 10 seconds, a controller can
change setpoints, get current setpoints, and request the setpoints that are supported by thermostat.