Holtkamp Electronics DUO 8600XL techn. stand 05.2016 4033_05.2016 V01.2021
- 7 -
8.2 Mounting notes
● This device may only be mounted on a suitable surface.
● The device must be sufficiently secured, take into consi-
deration the weight of the inserted coins. There are 6 holes
in the back of the casing to accomplish the mounting pro-
cess. Screws and dowels are included by delivery.
● The device must be mounted horizontally and vertically to
guarantee a flawless function of the coin receiver. That
means the angle of the device can only be maximum 2 º,
sloping forward or backward, as well as to the right or the
left.
● The device must be mounted perpendicular and horizontally,
to avouch a faultless function of the coin acceptance.
That implies, the tilt angle of the device can only be maxi-
mal 2° forwards or backwards and maximal 2° to the right or
left.
● The input cables are fixed by three drilled holes in the rear
wall. The device is corresponding to protection type IP 20
and may only be used in dry rooms. Choose a cable cross
section of the feed line adequate big. Attend thereby the
connected electrical load. Attend to the VDE guidelines.
8.3 Mounting instructions
● Shut down the power input, by activating the immobilising
switch, the fuse or even the main safety fuse.
● Unlock and remove the coin box.
● Loosen the two screws of the fuse plate, remove the fuse
plate and raise the casing so that it is possible to pull out
the electrical connectors. Pull out the electrical plug connec-
tions and remove the casing completely.
● The wall plate horizontal and vertically align with the help
of a level.
The tilt angle can only be 2° now mark the drilled holes.
● Drill the holes and insert suitable dowels. Through the holes
“15” (see image 1.1 of the device) on the rear wall connect
up the electricity. With the appropriate screws secure the
casing tightly. Now reinstall the electrical connections.
Place the casing on the fixing bolts “14”. As a counter mea-
sure place the fuse plate, through the opening of the remo-
ved coin box, on the fixing bolts “13” and tighten with the
supplied screws.
8.4 Electrical connection
The electrical connection can only be carried out by
authorized and qualified personnel!
The electrical connection has to be carried out by the local VDE
regulations. With a permanent connection, an all pole mains se
-
parator with at least 3 mm contact gap must be used. Before star
-
ting the electric the corresponding circuit must be disconnected.
Shut down the mains input by activating the separator switch,
remove the fuse or release the main safety fuse. Mains and low
voltage cable must be spaced apart. Low voltage cables should
be generally spaced as screened cables.
Control cable and remote start connection have to
be kept away from each other.
ATTENTION:
The installation must be performed by authorized
personnel! Therefore, make sure that the installation
is carried out by an electronics specialist!
Connection 230V
Remote start
(potential free)