Holtkamp Electronics DUO 8600XL techn. stand 05.2016 4033_05.2016 V01.2021
- 26 -
14.6 Readout the code
Call up see under 14.5 “
Enquiring the failure statistics
”. After
advertisement of the error messages, go along with “
OK
” button.
The code is advertised:
The acceptation of the “H” numbers are divided as follows:
H1
= number of trader
H2
= number of customer
H3
= number of end-customer
H4 + H5 are not assigned (255)
Please note the first three “H” numbers ahead in your opera
-
ting instruction for potential questions resp. for new-order of chip
cards or new devices.
14.7 Cancelling the failure statistics
When you are in the normal mode, you can change to the stati
-
stic menu by hold pressed
PLUS
button and insert chip card type
43. Unhand the
PLUS
button. With
OK
button you change to the
error message which should be deleted. Press the
PLUS
and
RESET
button at once, the selected error statistic is cancelled.
You quit the menu with extraction the chip card.
15 Not programmable special equipments
15.1 Electric contactor 2 x 20 A or 4 x 20 A on
request
The electric contactor offers the possibility to increase the swit
-
ching power of the DUO. If you have ordered your DUO with an
electric contactor, it will be installed on the SB frame inside on
the back side of the casing.
15.2 Extra connection for time stop
The extra connection for time stop offers the possibility, to inter
-
rupt the main time count-down with an external switch (e.g. flow
sensor). If your DUO has been ordered with an extra connection
for time stop, you will find on the SB frame, on the inside back
side of the casing a 2-pole screw-terminal to connect an external
switch (potential free closing contact). This special equipment
cannot be ordered together with the special equipment, cleaning
button or an external short impulse for the washing machine door.
15.3 Power depending time stop
The power depending time stop offers the possibility, to interrupt
the main time, dependent on the power input of the connected
device. If the power input is under 40, 80 or 100 mA (as ordered),
the main time count-down will be interrupted.
15.4 Extra connection for cleaning button
The extra connection for the cleaning button offers the possibility,
to disable the connected device after every use, until an external
button has been pressed. The disabled condition is shown by the
word "cleaning" blinking in the display. If you have ordered your
DUO with an extra connection for a cleaning button, you will find
on the SB frame, on the inside of the back side of the casing a
2-pole screw terminal to connect an external button (potential
free closing contacts). This special equipment can´t be ordered
together with the special equipment time stop or an external
short impulse for the washing machine door.
15.5 Internal short time impulse for washing
machine door opening
The short time impulse for the washing machine door opening,
offers the possibility, using the RESET key or by inserting a
chip-card type 11, to turn on the connected appliance for 30
seconds. This function is deactivated for 60 seconds after every
short time impulse. This special equipment can´t be ordered to
-
gether with the special equipment, cleaning button or time hold.
15.6 Potential free relay contact
If you have ordered your DUO with potential free relay contacts,
the closing contacts of the main relay or the run-out, will be vol
-
tage free on the screw terminals. These terminals are on the SB
frame, inside of the back side of the casing.
15.7 Key switch for free use
The key switch for free use, offers the possibility, to use the at
-
tached appliance, with the help of the built in key switch, without
paying as long as the key switch is on.
15.8 Connection possibility for Cancel button
The connection possibility for the cancel button allows cancelling
pre-run and main time with an external button. The run-out time
can´t be cancelled. If you have ordered your DUO with an extra
connection for a cancel button, you will find on the SB frame,
on the inside rear wall of the casing a 2-pole screw terminal, to
connect an external button (potential free, closing contacts). Or a
button on the casing will be used.