Holtkamp Electronics DUO 8600XL techn. stand 05.2016 4033_05.2016 V01.2021
- 14 -
Display ad
Factory setting
Description
Service interval 2
0 hrs
The service interval 2 offers the possibility for further note operating hours.
When the service hour counter 2 reaches the operating hours, an exclamation
mark will be shown on the display and signals the need of service. By can
-
celling the service hour counter 2 the exclamation mark is also deleted. The
service interval is adjustable in hour steps up to 999 hours. If “
0
” hours are set,
the function is disabled.
Service interval 3
0 hrs
The service interval 3 offers the possibility to note operating hours. When the
service hour counter 3 reaches the operating hours, an exclamation mark will
be shown on the display and signals the need of service. By cancelling the
hours counter 3 the exclamation mark is also deleted. The service interval is
adjustable in hour steps up to 999 hours. If “
0
” hours are set, the function is
disabled.
Hours/
Minutes
no
Indicating the hours/minutes offers the possibility to show the main time in
minutes and seconds or in hours, minutes and seconds.
● If “
yes
” is set, then the display will show the time in hours and minutes.
● If “
no
” is set, then the display will show the time in minutes.
Minimum
insert
yes
The minimum insert offers the possibility to convert, under the price settings,
the minimum price. The minimum price is the amount, which needs to be in
-
serted to each main time. Once the first main time has been bought, inserting
more coins permits the further buying of the next period.
● By activating minimum insert can be used the function “price step card”.
● If “
yes
” is set, is the minimum insert activated.
● If “
no
” is set, is the minimum insert deactivated.
HQL time
yes
The HQL Time offers the possibility to hinder the new start of a main time,
during the run-out time. The newly bought main time will be accounted with
the amount of remaining run-out time of the payment. If this function is not
activated then the run-out time is immaterial, the main time will start as soon
as the pre-run time has ended. Should the compulsory remote start be activa
-
ted (compulsory remote start active, when the lead time = 0), the device can
be started with the remote start button after the run-out time has expired.
● If “
yes
” is set, is the HQL time activated.
● If “
no
” is set, is the HQL time deactivated.
Purchase lock by
OR
no
The purchase lock by run-out offers the possibility to block the buying of main
time during the run-out time. By activating this option the coin insert and chip
card are blocked during the run-out time. Buying time during run-out time is
impossible.
● If “
yes
” is set, the purchase lock by run-out is activated.
● If “
no
” is set, the purchase lock by run-out is deactivated
Pre-run relay
no
The pre-run relay offers the possibility to switch the fan on at the beginning of
the pre-run time. They remain switched on until run-out time is ended. When
the pre-run time is set to 0, the fan will start by activating the remote start and
stays on until the end of the run-out time.
● If “
yes
” is set, the pre-run relay is activated.
● If “
no
” is set, the pre-run relay is deactivated.