136
7-4
4
P
A
B
S
4
7-5
Q
Q1
S1
User Code
* = Factory confi guration
Stop
of the wheel when the wheel guard is lifted
during the measuring run
(
Fig
.
7-4
) Select; (
4
), (
A
), (
P
),
Disabled
= Stop deactivated
THE WHEEL ROTATES WHEN THE WHEEL GUARD
IS OPEN.
MAKE SURE THAT THE WHEEL IS NOT BLOCKED
BY A TOOL OR SIMILAR ITEM.
WEAR SAFETY GOGGLES AND TIGHTLY FITTING
WORKING CLOTHES.
Enabled
(*) = Stop activated
After the
confi rmation, this operating mode can
be acquired in the permanent memory
(
Fig. 7-6
).
Number of revolutions per measuring run - 5 to 20
revolutions possible, factory–set to 10*
(
Fig
.
7-5
) Select; (
4
), (
B
), (
Q
), (
Q1
),
—
Rotate the shaft to change the value.
—
Type on the value set.
Warning
Reducing the number of measurement revolutions will
reduce the accuracy of measurement.
After the confi rmation, this operating mode can
be acquired in the permanent memory
(
Fig. 7-6
).
Selecting the limit (threshold) value for suppression
of minor unbalance readings in grams, or ounces.
(
Fig
.
7-5
) Select; (
4
), (
B
), (
S
), (
S1
),
Grams:
Range 3.5 to 20 g
Factory-adjusted value is 3.5 g
Threshold value display, e.g.: 3.5 g
—
Select another limit.
—
Type on the value set.
Ounces:
Range 0.12 to 0.71 oz
Factory-adjusted value is 0.12 oz
Threshold value display, e.g.: 0.12 oz
—
Select another value, e.g.: 0.2 oz
—
Type on the value set.
After the confi rmation, this operating mode can
be acquired in the permanent memory
(
Fig. 7-6
).
..
..
..
.
..
. .
..
.
Grams:
Range 3.50 to 20.0 g
Factory-adjusted to 5.0* g
Select another limit, e. g.: 5.50 g
•
Select Code C8
•
Set the value 5.50
•
Press
ENTER
Ounces:
Range 0.12 to 0.71 oz
Factory-adjusted to 0.18* oz
Select another limit, e. g.: 0.50 oz
•
Select Code C8
•
Set the value 0.50
•
Press
ENTER