Input: Code/state
Display: Code/state
-
-
+
+
to 10
to 1
Back to working mode
74
-
-
+
+
to 12
to 1
Back to working mode
75
76
-
-
-
+
+
+
to 13
to 0
to 1
C10
C10
1
XXX
XXX
C12
C12
1
222
123
XXX
XXX
C13
C13
0
C13
1
Changing modes of operation
Code C10
Fig. 74
Storing the selected modes of operation in the
permanent memory
0* = No storage
1 = Data are stored in the permanent memory
•
Store in the permanent memory - a three-tone signal is
given to acknowledge acceptance.
If the mode stored in the permanent memory is to be changed,
enter the desired state (e. g. on or off) for the mode in ques-
tion and transfer it via code C10 into the permanent memory
(not possible for code C4).
Code C12
Fig. 75
Readings of numbers of measuring runs
Example: 222,123 measuring runs so far performed By press
-
ing the FINE key an turning the wheel the following counters
can be displayed:
1 = Total number of measuring runs
2 = Number of measuring runs where balance quality was
considered OK
3 = Number of Pro-Matches performed
4 = Number of measuring runs in service mode
5 = Number of measuring runs since the last calibration
Maximum count is 999,999 runs. Once this number is
reached, the counter is reset to zero.
Code C13
Fig. 76
Starting the mesuring run by closing of (optional)
wheel guard
0* = Start via START key 1
= Start via wheel guard
The selected mode of operation can be transferred to the
permanent memory.
* = Factory adjusted mode
Operation manual geodyna 2600 EEWB703D
37