Controls and displays
4. Controls and displays
Fig. 8
Overview
1 START
key
Start a
measuring run
2 STOP
key
- Interrupt the measuring run
- Delete an error code
- If input of a mode of operation is completed with
the STOP key, the new state is deselected automatically
and the former state is re-established.
3
Function keys
(see
Fig. 9
to
11
)
4
Display (see
Fig. 12
to
15
)
Fig. 9
Function keys on the left
1
Function key for
distance rim / machine
2
Function key for
rim width
3
Function key for
rim diameter
Fig. 10
Function keys in the center
4 PRO MATCH
- Starts an optimisation program (LED PRO MATCH
lights).
- In the Pro-Match program (OP program): enter valve
position.
5 CLEAR/RESTORE
CLEAR
(key pressed briefly): Setting the factory adjusted
modes of operation. All settings are deleted and the
display returns to standard.
RESTORE
(key pressed for 3 seconds): Restores all
modes the way they were before clear was pressed.
6 CALIBRATE/CODE
CALIBRATE
(key pressed briefly): Sets the machine in
the user calibration mode (see § 13.
User calibration).
CODE
(key pressed for 3 seconds): Switches to changing
modes of operation.
7 G/OZ
Switches over the weight unit for unbalance readings
(grammes or ounces).
G
Readings in grammes
Oz
Readings in ounces
When the machine is switched on the weight unit set with
code C3 is active.
Operation manual geodyna 2600 EEWB703D
7