1
15
16
START
8
2
3
4
5
inch mm
7
6
12
Operation manual geodyna 2600 EEWB703D
Controls and displays
Fig. 15
Display panel - section on the right
1
Loudspeaker
symbol
2 inch/mm
The unit of measurement (inch or mm) is chosen by using
the rim diameter key.
3 Rim diameter
lights whenever rim diameter key is pressed.
4
Digital display of
right correction plane
to show:
- rim diameter
- distance rim/machine (always in mm)
- amount of unbalance of right correction plane
- state of modes of operation or preset limit values
5 Direction indicator
of right correction plane
6
Indicates when
correction position in the right
correction plane
has
been
reached
.
7 Distance machine/left correction plane
lights whenever distance key is pressed or gauge arm for
distance and rim diameter is moved.
8 START
flashes when the START key is to be pressed during pro
match and operator calibration.
Fig. 16
Pedal of main shaft lock
The main shaft is locked when the pedal is depressed. This
will facilitate tightening or untightening of the clamping nut, as
well as retaining the wheel in correction position for correct
fitting of the balance weights.
This lock is designed only to facilitate orientation of the wheel
and must not be used for braking the main shaft.