2.0 Installation
Install the machine in a covered and dry place. Operation
temperature is +41/+122 °F (+5/50° C). The machine can
work below 32 °F (0° C), but some minor modifications
are required: contact your
Hofmann
distributor for detailed
information.
A.
Remove the screws that attach the machine to the
pallet.
B. Lift the machine with an appropriate lifting tool (crane,
fork lift) and a belt of sufficient capacity (3500 N).
For this operation, it is required to be helped by a second
person. Always mind the center of gravity of the machine
(Fig 2.0-1).
BE CAREFUL NOT TO DAMAGE THE AIR HOSES.
C.
Remove the safety means from the mounting arm.
D.
When first setting the machine into operation, check
hose connections and unions for leakage.
E.
The machine must be secured to the floor through
the holes provided in the cabinet.
Expansion screws 12x120mm shall be used.
Drill 12mm holes in the floor flush with the holes provided
in the cabinet.
Place the nogs into the holes drilled in the floor and move
the machine so that the holes of the cabinet are flush with
the holes in the floor. Tighten the screws at 70 Nm (51
ftxlb).
2.1 Electrical Installation
WARNING
ALL ELECTRICAL CONNECTIONS SHALL BE
PERFORMED BY A LICENCED TECHNICIAN. ALL
SERVICE MUST BE PERFORMED BY AN
AUTHORIZED SERVICE TECHNICIAN.
FOR ELECTRIC MOTOR TYPE ONLY:
Check that the electrical specifications of the power source
are the same of the machine. The machine uses 0.75
kW. Electric specifications are clearly marked on a label
at the end of the electric cord.
If the plug is provided disregard this paragraph.
Connect the electric cord of the machine with an approved
plug. The ground cable (green and yellow) must be
properly connected.
WARNING!
FAILURE TO PROVIDE PROPER ELECTRICAL
SUPPLY AND GROUNDING WILL CREATE A SHOCK
HAZARD TO THE OPERATOR.
NOTE
: AIR MOTOR POWERED MACHINE DOESN’T
NEED ELECTRICAL INSTALLATION.