Operation
manual geodyna 6300-2 – ZEEWB511B03 Mode d’emploi geodyna 6300-2 – ZEEWB511B03
Changing modes of operation
Code C0
Fig. 74
Setting the factory-adjusted modes of operation
(see § 5. Switching on the machine)
0* =
No action
1 =
Set default values
(state 1 is only shown briefly)
The selected mode of operation can be transferred to the per-
manent memory.
Code C1
Fig. 75
Selecting the resolution of unbalance readings in
1 or 5 g, or 0.05 or 0.25 oz increments
0* =
5 g (0.25 oz) increments
1
=
1 g (0.05 oz) increments
The selected mode of operation can be transferred to the per-
manent memory.
Code C2
Fig. 76
Selecting suppression of minor unbalance readings
0 =
Suppression
off
1* =
Suppression
on
The selected mode of operation can be transferred to the per-
manent memory.
* = Factory adjusted mode
Sélection du mode de fonctionnement
Code C0
Fig. 74
Etablir les modes de fonctionnement programmés
par le fabricant (voir § 5. Mise en circuit de la ma-
chine)
0* = Aucune
action
1
=
Etablir les valeurs programmées par le fabricant
(l’état 1 n’est affiché que brièvement)
Le mode de fonctionnement choisi peut être transféré à la mé-
moire permanente.
Code C1
Fig. 75
Choix des échelons pour l’affichage du balourd de
1 ou 5 g, ou 0,05 ou 0,25 oz
0* =
Echelons de 5 g (0,25 oz)
1
=
Echelons de 1 g (0,05 oz)
Le mode de fonctionnement choisi peut être transféré à la mé-
moire permanente.
Code C2
Fig. 76
Sélection de la suppression de faibles balourds
0 = Suppression
déclenchée
1* = Suppression
enclenchée
Le mode de fonctionnement choisi peut être transféré à la mé-
moire permanente.
* = Programmé par le fabricant