Appendix B
–
Communications 17
HP-310
Messages
Commands Supported By Communications Messages
Command
Description/Allowed Data/Response
DN
Tag Number
“0” to “99999999”
“TAG NUM = (DATA)”
The first three digits are the units code for total. Changing
these digits will change the TU settings.
FC
Linearization
“0”
= Average K factor
“1”
= Linearization table
“F C METHOD = AVG”
for Average K factor
or
“F C METHOD = LIN”
for Linearization table
KD
K Factor Decimal Point Location
“0”
for 00000000.
“1”
for 0000000.0 and all K Factors are less than
9999999.9, otherwise not allowed
“2”
for 000000.00and all K Factors are less than 999999.99,
otherwise not allowed
“3”
for 00000.000 and all K Factors are less than
99999.999, otherwise not allowed
“K-FAC DECL=(DATA)”
AK
Average K Factor
“0.001”
to
“99999.999”
if KD = 3
“999999.99”
if KD = 2
“9999999.9”
if KD = 1
“ 99999999”
if KD = 0
“AVG KFAC =(DATA)”
NP
Number Points in the Table
“2”
to
“20”
“NUM PTS =(DATA)”