c
Flush cooling system and change coolant.
j) Seasonal Maintenance Checks Spring/Fall (Engine)
(1) Check Fan Mounting
a
Check fan to be sure it is securely mounted.
b
Check for fan wobble and/or broken/cracked blades.
c
Check fan hub and crankshaft pulley for secure mounting.
4
2
3
1
1. Fan
Pulley
2. Vibration
Damper
3. Alternator
4. Belt Tensioner
Engine Accessories
Figure 3
(2) Check cooling system each spring and fall. Clean if necessary.
(3) Check All Hoses.