![Hiwin MAGIC-01-14-EN-2207-MA Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/hiwin/magic-01-14-en-2207-ma/magic-01-14-en-2207-ma_assembly-instructions-manual_2140509017.webp)
Assembly instructions
Assembly
HIWIN MAGIC Distance Measuring Systems
MAGIC-01-14-EN-2207-MA
Page
17
of
32
Clean the cover strip with a suitable cleaning agent.
Place the cover strip on the profile rail
Fig. 4.7: Cover strip with finished ends and distance L
S
Table 4.3: Strip end distance
Size
Distance L
S
[mm]
15
5.0
20
8.0
25
9.5
30
10.0
35
10.0
45
11.0
55
12.0
65
14.5
Maintain distance L
s
in accordance with Table 4.3.
Starting from one side, clamp the cover strip onto the profile rail over a length of approx. 15
cm.
Press down the cover strip fold on the reference side of the profile rail.
Starting from the front side, press on the second fold of the cover strip.
Fig. 4.8: Fitting the beginning of the tape
The cover strip is resting flush on the upper side of the profile rail.