Contents
Linear motor axis LMSSA
LMSSA-01-1-EN-2201-MA
Seite 18 von 44
Note:
Electrical equipment is designed to withstand to protect against the effects of transportation, and storage
temperature within a range of -25 °C to +55 °C and for short periods not exceeding 24h at up to +70 °C.
Steps to transport the linear motor system:
Disconnect power supply.
Disconnect stage cables.
Remove the payload.
To transport the linear axis, hoist it at the points designated A and B (Fig. 4.1).
Ensure even load distribution while lifting.
Fig. 4.1: Hoisting and transporting – here for a linear motor system
Fig. 4.2: Hoisting and transporting – Incorrect position of the supporting points
4.3
Requirements at the installation site
4.3.1
Ambient conditions
Area of use
For indoor use only
Temperature
0 °C bis 50 °C
Humidity
< 80% RH (non-condensing)
Altitude
< 1000 m
Installation site
Flat, dry, vibration-free
Protection class
IP50 and no interference from corrosive solvent or strong magnetic
Grounding
Plant power grounding line conforms to international requirements
Avoid exposing to direct sunlight or hear rays.
Away from electric magnetic interference source sites, such as welding, discharge machine.