8
Troubleshooting
Table 8.1: Fault table
Fault
Possible cause
Remedy
Motor does not start
Supply lines disconnected
Check connections, plug contacts may be
compressed, repair if necessary. The connectors
have seals, which means that a certain screw
connection resistance must be overcome.
Fuse has tripped via motor
protection
Check motor protection for the right settings,
remedy defects if necessary.
Upon restart, the drive reports a
fault during commutation
Motor phases connected
incorrectly
Check rotational direction.
Encoder counting direction
incorrect
Change the sin and cos pair of wires in the encoder
plug.
Forcer housing is too close to the
limit switch/limit stop
Disconnect power supply to axis and move forcer
housing manually into the center of the axis.
Additional drive resistance e.g.
sealing lip, without parameter
adjustment
Change parameters in the drive amplifier.
Axis overspeeds upon restart
Commutation incorrect
See fault during commutation.
Check commutation parameters in the drive, activate
speed monitoring!
EMC interference with the encoder
signal
Check the shielding of the connectors and cables.
Axis overspeeds in positioning
mode
Programming error in the position
transfer, invalid acceleration
ordered
Activate security settings in the drive amplifier, such
as speed monitoring, permissible position errors etc.
Motor heats up too much
(measure temperature)
Rated power exceeded as duty
cycle is too long
Adapt load cycle to the rated power of the motor.
Cooling insufficient
Rectify cooling air supply or open cooling air
passages, retrofit external fan if necessary.
Forcer housing is difficult to move Check lubrication of the guideways, foreign bodies in
the traversing range?
Ambient temperature too high
Observe permissible temperature range.
Load cycle has been modified
Calculate load cycle and adapt accordingly.
Drive amplifier motor
commutation does not function
properly
Adapt commutation parameters of the drive
amplifier.
Operating noise from the forcer Relubrication required otherwise
risk of bearing damage
Lubrication or consultation with HIWIN
The axis generates cracking
noises when it is subject to
control
EMC interference in the encoder
signal
Encoder cables must be used separately with
shielded sin and cos signal pairs.
Commutation incorrect
Optimize commutation parameters.
The forcer jerks while moving
and generates operating noise
that is not caused by the profile
guideways
EMC interference in the encoder
signal, encoder cable plug
connection defective, pin bent in
plug
Place motor cable and/or encoder cable shield in
full contact with the earthing terminal of the
amplifier, check pin in plug
Position discrepancies after
several hours of operation
Use mains filter to stabilize voltage
Содержание LMSSA
Страница 1: ...MM03UE01 1704 Assembly instructions Linear motor axis LMSSA LMSSA 01 1 EN 2201 MA www hiwin de...
Страница 41: ...Linear motor axis LMSSA LMSSA 01 1 EN 2201 MA Seite 41 von 44...
Страница 42: ...Linear motor axis LMSSA LMSSA 01 1 EN 2201 MA Seite 42 von 44...
Страница 43: ...Linear motor axis LMSSA LMSSA 01 1 EN 2201 MA Seite 43 von 44...