Advanced System Set Up
The system will be set to its default parameters when powered on for the first
time. The screen displays the following information in sequence and the user can
change any given value on each screen.
To change a parameter value in the program, press START/ENTER to make that
value blink. Next, change the value by pressing INC or DEC. The value will be
stored by pressing START/ENTER once.
ITEM
SELECTION
DESCRIPTION
OFF / ON
(1-720 Min.)
When you start a charge process, the
integral safety timer automatically
starts running at the same time. This is
programmed to prevent overcharging
of the battery if it proves to be faulty, or
if the termination circuit cannot detect
the battery is full. The value for the safety
timer should be generous enough to
allow a full charge of the battery.
OFF / ON
(100-50,000 mAh)
This program sets the maximum charge
capacity that will be supplied to the
battery during charge. If the delta peak
voltage is not detected nor the safety
timer expired for any reason, this feature
will automatically stop the process at the
selected capacity value.
OFF / ON
(20ºC / 68ºF -
80ºC / 176ºF)
The battery’s internal chemical reaction
will cause the temperature of the battery
to rise. If the temperature limit is reached,
the process will be terminated.
Celsius /
Fahrenheit
You can choose the temperature
displayed by Celsius or Fahrenheit as
you like.
1-60 Min.
A rest time allowing the battery to cool
down between charging/discharging cycle.
Safety Timer
ON 720 Min
Capacity Cut-Off
ON 5000 mAh
Temp Cut-Off
ON 50 C / 122 F
Temperature Unit
Celsius
Rest Time
CHG > DCHG 10 Min
°
°