30
Pb Lead-Acid Battery Program
[
cont.]
Pb Charge Mode:
BEFORE YOU BEGIN CHARGING YOUR BATTERY, MAKE SURE YOU
HAVE READ AND UNDERSTAND ALL OF THE WARNINGS AND SAFETY
INFORMATION CONTAINED ON PAGES 02-07.
After selecting the correct battery type, use the
+
or
▬
buttons to change it to the
“CHARGE“ mode.
Press the
►
button and the amp rate value will begin flashing. Use the
+
or
▬
buttons to adjust the value to the desired charge rate. The amp rate should be set
to 1/10 of capacity. For example, if you are charging a 7Ah battery the charge rate
should be set to 0.7A. Follow the instructions provided with your battery when
setting the amp rate.
Press the
►
button again and the voltage rate value will
begin flashing. Use the
+
or
▬
buttons to set the voltage
and number of cells.
Press and hold the
►
button and charging will begin.
Once charging has commenced, the charger will display
the following real-time information: battery type, charging
current, battery voltage, charging time and charged capacity.
When charging is complete, the screen will read “FINISHED” and the charger will emit
a chiming sound.
Pb Discharge Mode:
BEFORE YOU BEGIN CHARGING YOUR BATTERY, MAKE SURE YOU
HAVE READ AND UNDERSTAND ALL OF THE WARNINGS AND SAFETY
INFORMATION CONTAINED ON PAGES 02-07.
After selecting the correct battery type, use the
+
or
▬
buttons to change it to the
“DISCHARGE“ mode.
Press the
►
button and the amp rate value will begin flashing. Use the
+
or
▬
buttons to adjust the value to the desired charge rate. The amp rate should be set
to 1/10 of capacity. For example, if you are discharging a 7Ah battery the discharge
rate should be set to 0.7A. Follow the instructions provided with your battery when
setting the amp rate.
Warning
Pb Charge
1.5A 12.0V(6P)
P-6 1.5A 13.56V
CHG 002:22 00106
Warning