37
Per Cell Discharge Voltage:
Press the
►
button and the
per cell discharge voltage value will begin to flash. Use
the
+
or
▬
buttons to change the per cell discharge voltage, then press the
►
button to confirm your selection.
MAKE SURE TO FOLLOW YOUR BATTERY MANUFACTURER’S
RECOMMENDATIONS REGARDING DISCHARGING. FAILURE TO DO SO
MAY DESTROY THE BATTERY OR RENDER IT UNSAFE FOR USE.
Terminal Voltage:
Press the
►
button and the terminal
voltage value will begin to flash. Use the
+
or
▬
buttons
to change the terminal voltage, and then press the
►
button to confirm your
selection.
CHANGING THE TERMINAL VOLTAGE IS ONLY INTENDED FOR EXPERT
USERS, ANY CHANGES TO DEFAULT SETTINGS ARE COMPLETELY AT YOUR
OWN RISK.
Save Program:
Press the
►
button to save the program.
SAVE…..
will appear momentarily while the program is
written to the memory.
Once saved, the screen indicates the memory number,
battery type, cell count, charge current and discharge
current.
Recall Memory:
From the BATT/PROGRAM menu use the
+
or
▬
buttons to
scroll to the BATT MEMORY program and press
►
button to
enter the battery memory program . Use the
+
or
▬
buttons to scroll through the
memories. When you have found the memory you would like to use, press the
►
button again to recall the memory.
Use the
+
or
▬
buttons to scroll the available process
(charge, discharge, balance charge etc.). Select the process
you would like to execute for the battery then press and hold the
►
button for 3
seconds to begin the selected process.
Memory Preset - Data Save/Load
[
cont.]
DSCH VOLTAGE
3.0V/CELL
Warning
TVC = YOU R RISK
4.20V
Warning
SAVE PROGRAM
ENTER
SAVE PROGRAM
SAVE...
[ BATT MEMORY 1 ]
LiPo 7.4V (2S)
[ BATT MEMORY 1 ]
C:4.9 D:2.2 A
ENTER CHARGER
LOAD...
LiPo BALANCE CHG
4.9A 7.4V (2S)