NiCd/NiMH Battery Program
[
cont.]
Follow the instructions provided with your battery when setting the voltage
cutoff. The X2 AC Pro will stop discharging when the battery has reached the
preset voltage cutoff.
Press and hold the
►
button to begin discharging. Once
discharging has commenced, the charger will display
the following real-time information: battery type, discharging current, battery
voltage, discharging time and discharged capacity.
When discharging is complete, the screen will read “END:
CUTOFF-VOL” and the charger will emit a chiming sound.
The charger will display the elapsed time, end voltage and number of mAh
discharged.
You can press the
■
button at any time during the charging process to stop the
discharge process.
NiCd/NiMH Re-Peak Mode:
BEFORE YOU BEGIN CHARGING YOUR BATTERY, MAKE SURE YOU
HAVE READ AND UNDERSTAND ALL OF THE WARNINGS AND SAFETY
INFORMATION CONTAINED ON PAGES 02-07.
Applicable to NiMH and NiCd batteries only, in re-peak mode the charger can
peak charge the battery once, twice, or three times in a row automatically. This
process is good for confirming the battery is fully charged and for verifying how
well the battery can accept a fast charge. A five-minute cool-down delay occurs
after each Re-Peak charge.
IN RE-PEAK MODE, THE X2 AC PRO USES THE CHARGE AMPERAGE AND
VOLTAGE SETTINGS ENTERED IN CHARGE MODE (SEE PAGE 16).
After selecting the correct battery type, use the
+
or
▬
buttons to select the “RE-PEAK” mode. Press the
►
button
and Re-Peak cycle number 1 begins to flash on the screen. Use the
+
or
▬
buttons to scroll through and set up to 3 total cycles.Press the
►
button to begin
the Re-Peak process.
NiMH 1.3A 10.42V
AUT 002:22 00106
[TIME: 00:04:04]
9.6V 00640mAh
Warning
Note
NiMH RE-PEAK