31
X1 MF
Capacity
Current
Safety T ime
2000mAh 2.0A (2000/2.0=1000)/11.9=84 minutes
3300mAh 3.0A (3300/3.0=1100)/11.9=92 minutes
1000mAh
1.2A
(1000/1.2=833)/11.9=70 minutes
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
with enough time to charge 140% of the battery’s rated capacity. Delta
Peak termination should, under normal circumstances, end the charge
process within this allotted time.
Capacity Cut-Off
ON 5000mAH
Key Beep ON
Buzzer ON
Input Power Low
Cut-Off 11.0V
Ext. Temp 0C
Int. Temp 38C
For example:
Similiar to the Safety Timer, Capacity Cut-Off
allows you to limit the maximum charge capacity
of the charging process. Limiting a charge
process on a 1200mAh battery to 1300mAh, for
example, can protect against extreme overcharg-
ing. Consult your battery manufacturer’s recom-
mendation for limits.
Key Beep refers to the audible sound emmitted
every time you press a button on the X1 MF.
Buzzer refers to the sounds emitted when a
process is complete, a cycle changes, or there is
an error state detected. You can silence these
audible alerts in this setting.
The X1 MF can operate on DC power between
11-18V. High current charging processes will
“sag” the incoming voltage so a low voltage
threshold can be set to insure uninterrupted
charging and maintian charging rates.
Internal and external temperatures can be
displayed. External temperature status requires
the use of the optional Temperature Sensor Cable,
PN #44159.