Reversing valve (heating on mode)
NOTE (9)
Notes:
(1) Condition for entering into Cool Dashed mode. When fan set to ÒHiÓ or ÒAuto modeÓ and temperature difference between indoor temperature and set temperature has a
corresponding compressor rpm (calculated value in Table 7) larger than WMAX.
(2) Cool Dashed will release when i) a maximum 25 minutes is lapsed and ii) room temperature is lower than set temperature Ð3 C (thermo off) and iii) when room temperature
has achieved setting temperature Ð1 C then maximum Cool Dashed time will be revised to 20 minutes. And iv) indoor fan is set to Lo and Med fan mode and v) change operation
mode.
(3) During Cool Dashed operation, thermo off temperature is set temperature (with shift value) Ð3 C. After thermo off, operation continue in Fuzzy control mode.
(4) Compressor minimum ÒONÓ time and ÒOFFÓ time is 3 minutes.
(5) During normal cooling mode, compressor maximum rpm CMAX will maintain for 60 minutes if indoor temperature is lower than CLMXTP. No time constrain if indoor temperature
is higher than CLMXTP.
(6) When fan is set to ÒHiÓ, compressor rpm will be limited to CKYMAX.
(7) When fan is set to ÒMedÓ, compressor rpm will be limited to CJKMAX.
(8) When fan is set to ÒLoÓ, compressor rpm will be limited to CBEMAX.
(9) During Cool Dashed, when room temperature reaches set temperature Ð1 C compressor rpm is actual rpm x DWNRATEC.
Temperature
Calculated
difference
compressor rpm
1.66
2265 min
Ð1
2
2435 min
Ð1
2.33
2600 min
Ð1
2.66
2765 min
Ð1
3
2935 min
Ð1
3.33
3100 min
Ð1
3.66
3265 min
Ð1
4
3435 min
Ð1
4.33
3600 min
Ð1
4.66
3765 min
Ð1
5
3935 min
Ð1
5.33
4100 min
Ð1
5.66
4265 min
Ð1
6
4435 min
Ð1
6.33
4600 min
Ð1
6.66
4765 min
Ð1
7
4935 min
Ð1
7.33
5100 min
Ð1
7.66
5265 min
Ð1
8
5435 min
Ð1
8.33
5600 min
Ð1
8.66
5765 min
Ð1
9
5935 min
Ð1
9.33
6100 min
Ð1
9.66
6265 min
Ð1
10
6435 min
Ð1
10.33
6600 min
Ð1
10.66
6765 min
Ð1
11
6935 min
Ð1
Table 2
D
TCMAX
Note:
1. See the data in Table 1 on
page 47 for each constant in
capital letters in the diagrams.
– 53 –
Содержание Summit RAC-50YH5
Страница 32: ... 30 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS 50FH5 INDOOR UNIT 47 5 60 205 220 ...
Страница 38: ...MODEL RAS 50FH5 CIRCUIT DIAGRAM 39 ...
Страница 39: ...CIRCUIT DIAGRAM MODEL RAC 50YH5 41 ...
Страница 41: ... 44 MODEL RAS 50FH5 RECEIVING P W B MARKING ON P W B COMPONENT SIDE SOLDERING SIDE ...
Страница 42: ... 45 MODEL RAC 50YH5 MAIN P W B Marking on P W B E D I S T N E N O P M O C ...
Страница 45: ... 51 ...
Страница 91: ... 103 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50YH5 ...
Страница 109: ... 121 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 50FH5 ...
Страница 113: ...RAS 50FH5 RAC 50YH5 HITACHI PM NO 0364E Printed in Malaysia ...