Chapter 2
Installation and Wiring
2-22
2.2.5 Selection and wiring of dynamic braking resistor (on 0.4 kW to 22 kW models)
The SJ700D-3 series inverter models with capacities of 0.4 to 22 kW have an internal dynamic braking circuit.
Connecting an optional dynamic braking resistor to RB and P terminals increases the braking torque.
Without a resistor
connected
With a resistor connected
Minimum connectable
resistor
Minimum
resistance
during
continuous
operation
(Ω)
Model
SJ700D-****
FF/FEF/FUF3
Motor
capacity
(kW)
Braking torque
(%)
Resistance of
connected
resistor (Ω)
Braking torque
(
%
)
Resistance
(Ω)
BRD usage
rate
(
%
)
004L
0.4
20
48
150 over
48
10
150
007L
0.75
20
48
150 over
48
10
150
015L
1.5
20
32
150 over
32
10
100
022L
2.2
20
32
150 over
32
10
100
037L
3.7
20
32
110
32
10
100
055L
5.5
20
16
140
16
10
50
075L
7.5
20
10
150 over
10
10
50
110L
11
10
10
110
10
10
50
150L
15
10
7.5
110
7.5
10
35
185L
18.5
10
7.5
90
7.5
10
35
220L
22
10
5
110
5
10
35
007H
0.75
20
100
150 over
70
10
300
015H
1.5
20
100
150 over
70
10
300
022H
2.2
20
100
150 over
70
10
300
037H/040H
3.7
20
70
150 over
70
10
200
055H
5.5
20
70
130
70
10
200
075H
7.5
20
70
150 over
35
10
150
110H
11
10
50
130
35
10
150
150H
15
10
35
140
24
10
100
185H
18.5
10
35
140
24
10
100
220H
22
10
35
110
20
10
100
Содержание SJ700-4000HFU2
Страница 16: ...Contents Appendix Appendix A 1 Index Index Index 1 ...
Страница 44: ...Chapter 2 Installation and Wiring 2 23 Memo ...
Страница 70: ...Chapter 3 Operation 3 25 Memo ...
Страница 246: ...Chapter 5 Error Codes 5 11 Memo ...
Страница 254: ...Chapter 6 Maintenance and Inspection 6 7 Memo ...
Страница 280: ...Chapter 8 List of Data Settings 8 17 Memo ...