Chapter 8 List of Data Settings
8 - 7
Default
Code
Function name
Monitored data or setting
_FF _FEF
_FUF
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
b034
Run/power-on warning time
0. to 9999. (0 to 99990), 1000 to 6553 (10000 to 655300) (hr)
0.
¯
{
4-64
b035 Rotational
direction
restriction
00 (enabling both forward and reverse rotations), 01 (enabling
only forward rotation), 02 (enabling only reverse rotation)
00
¯
¯
4-7
b036
Reduced voltage start selection
0 (minimum reduced voltage start time) to 255 (maximum
reduced voltage start time)
6
¯
{
4-42
b037
Function code display restriction
00 (full display), 01 (function-specific display), 02 (user setting),
03 (data comparison display), 04 (basic display)
04
¯
{
4-76
b038 Initial-screen
selection
00 (screen displayed when the STR key was pressed last), 01
(d001), 02 (d002), 03 (d003), 04 (d007), 05 (F001)
01
¯
{
4-78
Oth
e
rs
b039
Automatic user-parameter
setting function enable
00 (disabling), 01 (enabling)
00
¯
{
4-79
b040
Torque limit selection
00 (quadrant-specific setting), 01 (switching by terminal), 02
(analog input), 03 (option 1), 04 (option 2)
00
¯
{
b041
Torque limit (1) (forward-driving
in 4-quadrant mode)
0. to 200. (%), no (disabling torque limitation)
150.
¯
{
b042
Torque limit (2)
(reverse-regenerating in
4-quadrant mode)
0. to 200. (%), no (disabling torque limitation)
150.
¯
{
b043
Torque limit (3) (reverse-driving
in 4-quadrant mode)
0. to 200. (%), no (disabling torque limitation)
150.
¯
{
b044
Torque limit (4)
(forward-regenerating in
4-quadrant mode)
0. to 200. (%), no (disabling torque limitation)
150.
¯
{
4-92
b045
Torque limit LADSTOP enable
00 (disabling), 01 (enabling)
00
¯
{
4-94
T
o
rque lim
it
at
ion
b046
Reverse Run protection enable
00 (disabling), 01 (enabling)
00
¯
{
4-93
b050
Controller deceleration and stop
on power loss
00 (disabling), 01 (nonstop deceleration to stop), 02 (DC voltage
constant control, with resume), 03 ( without resume)
00
¯
¯
b051
DC bus voltage trigger level
during power loss
0.0 to 999.9, 1000. (V)
0.0
¯
¯
b052
Over-voltage threshold during
power loss
0.0 to 999.9, 1000. (V)
0.0
¯
¯
b053
Deceleration time setting during
power loss
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
1.00
¯
¯
b054
Initial output frequency decrease
during power loss
0.00 to 10.00 (Hz)
0.00
¯
¯
b055
Proportional gain setting for
nonstop operation at power loss
0.00 to 2.55
0.20
{
{
Non-
st
op
oper
a
tion at
m
om
en
tar
y
power
fa
ilur
e
b056
Integral time setting for nonstop
operation at power loss
0.000 to 9.999 /10.00 to 65.53 (s)
0.100
{
{
4-83
b060
Maximum-limit level of window
comparators O
0. to 100. (lower limit : b061 + b062 / 2) (%)
100
{
{
b061
Minimum-limit level of window
comparators O
0. to 100. (lower limit : b060 - b062 / 2) (%)
0
{
{
b062
Hysteresis width of window
comparators O
0. to 10. (lower limit : b061 - b062 / 2) (%)
0
{
{
b063
Maximum-limit level of window
comparators OI
0. to 100. (lower limit : b064 + b066 / 2) (%)
100
{
{
b064
Minimum-limit level of window
comparators OI
0. to 100. (lower limit : b063 - b066 / 2) (%)
0
{
{
b065
Hysteresis width of window
comparators OI
0. to 10. (lower limit : b063 - b064 / 2) (%)
0
{
{
b066
Maximum-limit level of window
comparators OI
-100. to 100. (lower limit : b067 + b068 / 2) (%)
100
{
{
b067
Minimum-limit level of window
comparators O/OI/O2
-100. to 100. (lower limit : b066 - b068 / 2) (%)
0
{
{
b068
Hysteresis width of window
comparators O/OI/O2
0. to 10. (lower limit : b066 - b067 / 2) (%)
0
{
{
b070
Operation level at O
disconnection
0. to 100. (%) or "no" (ignore)
no
¯
{
b071
Operation level at OI
disconnection
0. to 100. (%) or "no" (ignore)
no
¯
{
Window com
p
ar
a
tor
b072
Operation level at O2
disconnection
-100. to 100. (%) or "no" (ignore)
no
¯
{
4-71
Содержание SJ700-055HFF2
Страница 15: ...Contents xiii Appendix Appendix A 1 Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 43: ...Chapter 2 Installation and Wiring 2 21 ...
Страница 48: ......
Страница 51: ...Chapter 3 Operation 3 3 ...
Страница 63: ......
Страница 152: ...Chapter 4 Explanation of Functions 4 89 H034 H234 ...
Страница 161: ...Chapter 4 Explanation of Functions 4 98 ...
Страница 219: ...Chapter 4 Explanation of Functions 4 156 ...
Страница 232: ......
Страница 244: ......
Страница 252: ......
Страница 258: ...Chapter 7 Specifications SJ700 550 LFF2 LFUF2 5 Cable hole φ41 7 6 ...
Страница 260: ......