Chapter 4 Explanation of Functions
4 - 143
Coil No.
Item
R/W
Setting
0035h
LOG2 (logical operation result 2)
R
1: ON, 0: OFF
0036h
LOG3 (logical operation result 3)
R
1: ON, 0: OFF
0037h
LOG4 (logical operation result 4)
R
1: ON, 0: OFF
0038h
LOG5 (logical operation result 5)
R
1: ON, 0: OFF
0039h
LOG6 (logical operation result 6)
R
1: ON, 0: OFF
003Ah
WAC (capacitor life warning)
R
1: ON, 0: OFF
003Bh
WAF (cooling-fan speed drop)
R
1: ON, 0: OFF
003Ch
FR (starting contact signal)
R
1: ON, 0: OFF
003Dh
OHF (heat sink overheat warning)
R
1: ON, 0: OFF
003Eh LOC
(low-current
indication signal)
R
1: ON, 0: OFF
003Fh
M01 (general output 1)
R
1: ON, 0: OFF
0040h
M02 (general output 2)
R
1: ON, 0: OFF
0041h
M03 (general output 3)
R
1: ON, 0: OFF
0042h
M04 (general output 4)
R
1: ON, 0: OFF
0043h
M05 (general output 5)
R
1: ON, 0: OFF
0044h
M06 (general output 6)
R
1: ON, 0: OFF
0045h
IRDY (inverter ready)
R
1: ON, 0: OFF
0046h
FWR (forward rotation)
R
1: ON, 0: OFF
0047h
RVR (reverse rotation)
R
1: ON, 0: OFF
0048h
MJA (major failure)
R
1: ON, 0: OFF
0049h
Data writing in progress
R
1: Writing in progress, 0: Normal status
004Ah
CRC error
R
1: Error detected, 0: No error (*2)
004Bh
Overrun
R
1: Error detected, 0: No error (*2)
004Ch
Framing error
R
1: Error detected, 0: No error (*2)
004Dh
Parity error
R
1: Error detected, 0: No error (*2)
004Eh
Sum check error
R
1: Error detected, 0: No error (*2)
004Fh (reserved)
0050h
WCO (window comparator O)
R
1: ON, 0:FF
0051h
WCO (window comparator OI)
R
1: ON, 0:FF
0052h
WCO (window comparator O2)
R
1: ON, 0:FF
*1 Normally, this coil is turned on when the corresponding intelligent input terminal on the control circuit
terminal block is turned on or the coil itself is set to on. In this regard, the operation of the intelligent
input terminal has priority over the operation of the coil. If disconnection of the communication train
has disabled the master system from turning off the coil, turn the corresponding intelligent input
terminal on the control circuit block on and off. This operation turns off the coil.
*2 Communication error data is retained until an error reset command is input. (The data can be reset
during the inverter operation.)
Содержание SJ700-055HFF2
Страница 15: ...Contents xiii Appendix Appendix A 1 Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 43: ...Chapter 2 Installation and Wiring 2 21 ...
Страница 48: ......
Страница 51: ...Chapter 3 Operation 3 3 ...
Страница 63: ......
Страница 152: ...Chapter 4 Explanation of Functions 4 89 H034 H234 ...
Страница 161: ...Chapter 4 Explanation of Functions 4 98 ...
Страница 219: ...Chapter 4 Explanation of Functions 4 156 ...
Страница 232: ......
Страница 244: ......
Страница 252: ......
Страница 258: ...Chapter 7 Specifications SJ700 550 LFF2 LFUF2 5 Cable hole φ41 7 6 ...
Страница 260: ......