Chapter 8 List of Data Settings
8 - 4
Default
Code
Function name
Monitored data or setting
_FF _FEF _FUF
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
A041
Torque boost method selection
00 (manual torque boost), 01 (automatic torque boost)
00
¯
¯
A241
Torque boost method selection,
2nd motor
00 (manual torque boost), 01 (automatic torque boost)
00
¯
¯
A042
Manual torque boost value
0.0 to 20.0 (%)
1.0
{
{
A242
Manual torque boost value, 2nd
motor
0.0 to 20.0 (%)
1.0
{
{
A342
Manual torque boost value, 3rd
motor
0.0 to 20.0 (%)
1.0
{
{
A043
Manual torque boost frequency
adjustment
0.0 to 50.0 (%)
5.0
{
{
A243
Manual torque boost frequency
adjustment, 2nd motor
0.0 to 50.0 (%)
5.0
{
{
A343
Manual torque boost frequency
adjustment, 3rd motor
0.0 to 50.0 (%)
5.0
{
{
4-18
A044
V/F characteristic curve
selection, 1st motor
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control), 04 (0Hz-range
sensorless vector), 05 (vector with sensor)
00
¯
¯
A244
V/F characteristic curve
selection, 2nd motor
00 (VC), 01 (VP), 02 (free V/f), 03 (sensorless vector control), 04 (0Hz-range
sensorless vector)
00
¯
¯
A344
V/F characteristic curve
selection, 3rd motor
00(VC), 01(VP)
00
¯
¯
4-16
A045
V/f gain setting
20. to 100. (%)
100.
{
{
4-15
A046
Voltage compensation gain
setting for automatic torque
boost. 1st motor
0. to 255.
100.
{
{
A246
Voltage compensation gain
setting for automatic torque
boost, 2nd motor
0. to 255.
100.
{
{
A047
Slippage compensation gain
setting for automatic torque
boost, 1st motor
0. to 255.
100.
{
{
V/
f char
ac
ter
is
tic
A247
Slippage compensation gain
setting for automatic torque
boost, 2nd motor
0. to 255.
100.
{
{
4-18
A051
DC braking enable
00 (disabling), 01 (enabling), 02 (set frequency only)
00
¯
{
A052
DC braking frequency setting
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.50
¯
{
A053
DC braking wait time
0.0 to 5.0 (s)
0.0
¯
{
A054
DC braking force during
deceleration
0. to 100. (%)
0.
¯
{
A055
DC braking time for deceleration 0.0 to 60.0 (s)
0.0
¯
{
A056
DC braking/edge or level
detection for [DB] input
00 (edge operation), 01 (level operation)
01
¯
{
A057
DC braking force for starting
0. to 100.(%)
0.
¯
{
A058
DC braking time for starting
0.0 to 60.0(s)
0.0
¯
{
DC br
aking
A059
DC braking carrier frequency
setting
0.5 to 15.0(kHz)
5.0
¯
¯
4-20
A061
Frequency upper limit setting
0.00 or "1st minimum frequency limit" to "maximum frequency" (Hz)
0.00
¯
{
A261
Frequency upper limit setting,
2nd motor
0.00 or "2nd minimum frequency limit" to "maximum frequency, 2nd motor" (Hz)
0.00
¯
{
A062
Frequency lower limit setting
0.00 or "start frequency" to "maximum frequency limit"
(Hz)
0.00
¯
{
A262
Frequency lower limit setting,
2nd motor
0.00 or "start frequency" to "maximum frequency, 2nd motor limit"
(Hz)
0.00
¯
{
4-24
A063
Jump (center) frequency setting
1
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A064
Jump (hysteresis) frequency
width setting 1
0.00 to 10.00 (Hz)
0.50
¯
{
A065
Jump (center) frequency setting
2
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A066
Jump (hysteresis) frequency
width setting 2
0.00 to 10.00 (Hz)
0.50
¯
{
A067
Jump (center) frequency setting
3
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
A068
Jump (hysteresis) frequency
width setting 3
0.00 to 10.00 (Hz)
0.50
¯
{
A069
Acceleration stop frequency
setting
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
¯
{
Fr
equency u
pper
/l
ower
lim
it
and
jum
p
fr
equency
A070
Acceleration stop time frequency
setting
0.0 to 60.0 (s)
0.0
¯
{
4-25
A071
PID Function Enable
00 (disabling), 01 (enabling), 02 (enabling inverted-data output)
00
¯
{
A072
PID proportional gain
0.2 to 5.0
1.0
{
{
A073
PID integral time constant
0.0 to 999.9, 1000. to 3600. (s)
1.0
{
{
A074
PID derivative gain
0.00 to 99.99, 100.0 (s)
0.00
{
{
A075
PV scale conversion
0.01 to 99.99
1.00
¯
{
A076
PV source setting
00 (input via OI), 01 (input via O), 02 (external communication), 03 (pulse-string
frequency input), 10 (operation result output)
00
¯
{
A077
Output of inverted PID deviation 00(OFF), 01 (ON)
00
¯
{
A078
PID variation range
0.0 to 100.0 (%)
0.00
¯
{
PI
D contr
o
l
A079
PID feed forward selection
00 (disabled), 01 (O input), 02 (OI input), 03 (O2 input)
00
¯
{
4-26
Содержание SJ700-055HFF2
Страница 15: ...Contents xiii Appendix Appendix A 1 Index Index Index 1 ...
Страница 17: ......
Страница 22: ......
Страница 43: ...Chapter 2 Installation and Wiring 2 21 ...
Страница 48: ......
Страница 51: ...Chapter 3 Operation 3 3 ...
Страница 63: ......
Страница 152: ...Chapter 4 Explanation of Functions 4 89 H034 H234 ...
Страница 161: ...Chapter 4 Explanation of Functions 4 98 ...
Страница 219: ...Chapter 4 Explanation of Functions 4 156 ...
Страница 232: ......
Страница 244: ......
Страница 252: ......
Страница 258: ...Chapter 7 Specifications SJ700 550 LFF2 LFUF2 5 Cable hole φ41 7 6 ...
Страница 260: ......