1–2
1.2 Inverter specification
1.2.1 SJ300
Monitor Mode
Dis-
play
code
Function name
SJ300 monitor or data range
(digital operator)
Initial
data
Note
d001
Output frequency
monitor
0.00-99.99/100.0-400.0(Hz)
-
d002
Output current
monitor
0.0-999.9(A)
-
d003
Operation direction
monitor
F(forward)/o(stop)/r(reverse)
-
d004
PID feedback
monitor
0.00-99.99/100.0-999.9/1000. – 9999 . /
1000-9999/ 100- 999 (10000-99900)
-
d005
Intelligent input
terminal monitor
-
d006
Intelligent output
terminal monitor
-
d007
Frequency
conversion monitor
0.00-99.99/100.0-999.9/1000. – 9999 . /
1000-3996
-
d012
torque monitor
-300.-+300.%
-
d013
Output voltage
monitor
0.0-600.0 V
-
d014
Input electric power
monitor
0.0-999.9 kW
-
d016
Accumulated time
monitor during
RUN
0.-9999./1000-9999/ 100- 999 h
-
d017
Power ON time
monitor
0.-9999./1000-9999/ 100- 999 h
-
d080
Number of trip time
monitor
0.-9999./1000-6553(10000-65530) (time)
-
d081
Trip monitor 1
-
d082
Trip monitor 2
-
d083
Trip monitor 3
-
d084
Trip monitor 4
-
d085
Trip monitor 5
-
d086
Trip monitor 6
Trip Code, frequency(Hz), current(A),
voltage(V),RUN time(h) power ON time(h)
-
d090
Warning monitor
Warning code
-
F001
Output frequency
setting
0.0, starting frequency-Max. frequency
(2
n d
max. 3
r d
max. frequency)(Hz)
0.00
F002
1
st
acceleration time
0.01-99.99/100.0-999.9/1000. -3600.(s)
30.00
F202
2
nd
acceleration time
0.01-99.99/100.0-999.9/1000. -3600.(s)
30.00
F302
3
rd
acceleration time
0.01-99.99/100.0-999.9/1000. -3600.(s)
30.00
F003
1
st
deceleration time
0.01-99.99/100.0-999.9/1000. -3600.(s)
30.00
F203
2
nd
deceleration time
0.01-99.99/100.0-999.9/1000. -3600.(s)
30.00
F303
3
rd
deceleration time
0.01-99.99/100.0-999.9/1000. -3600.(s)
30.00
F004
Operation direction
selection
00(forward)/01(reverse)
00
(Note1) Change mode during run by selection of b031 (software lock selection).
(Note2) Do not forget to press “STR” key when you change the display.
(Note1)
(Example) FW, terminal 7,2, 1: ON
Terminal 8,6,5,4,3:OFF
ON
OFF
5 4
3 2
1
FW
7 6
8
(Example) Terminal 12,11:ON
AL, 15,14,13:OFF
ON
OFF
12
AL 15 14 13
Содержание SJ300 Series
Страница 39: ...Internal block diagram ...
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......