1- 8
Function mode
Code
Function name
SJ300 Setting range
Initial data
-FE/-FU/-F
Note
H001
Autotuning selection
00(Invalid)/01( Valid(the motor does not rotate) )/
02( Valid(the motor rotates))
00
H002
1
s t
motor constant selecti on
00(Hitachi general purpose motor data)/01( Autotuning data) /
02( Autotuning data with online autotuning)
00
H202
2
nd
motor constant selection
00(Hitachi general purpose motor data)/01( Autotuning data) /
02( Autotuning data with online autotuning)
00
H003
1
s t
allowable motor selection
0.20-75.0(kW) <0.2-160(kW)>
Set on
forwarding
H203
2
nd
allowable motor selection
0.20-75.0(kW) <0.2-160(kW)>
Set on
forwarding
H004
1
s t
motor pole selection
2/4/6/8(pole)
4
H204
2
nd
motor pole selection
2/4/6/8(pole)
4
H005
1
s t
speed response setting
0.001-9.999/10.00-65.53
1.590
H205
2
nd
speed response setting
0.001-9.999/10.00-65.53
1.590
H006
1
s t
stabilized factor
0. - 255.
100.
H206
2
nd
stabilized factor
0. - 255.
100.
H306
3
rd
stabilized factor
0. - 255.
100.
H020
1
s t
motor constant R1
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H220
2
nd
motor constant R1
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H021
1
s t
motor constant R 2
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H221
2
nd
motor constant R 2
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H022
1
s t
motor constant L
0.00-99.99/100.0-655.3( mH)
Set on
forwarding
H222
2
nd
motor constant L
0.00-99.99/100.0-655.3( mH)
Set on
forwarding
H023
1
s t
motor constant I
0
0.00-99.99/100.0-655.3(A)
Set on
forwarding
H223
2
nd
motor constant I
0
0.00-99.99/100.0-655.3(A)
Set on
forwarding
H024
1
s t
motor constant J
0.001-9.999/10.00-99.99/100.0-9999.( kgm
2
)
Set on
forwarding
H224
2
nd
motor constant J
0.001-9.999/10.00-99.99/100.0-9999.( kgm
2
)
Set on
forwarding
H030
1
s t
motor constant R1
(Autotuning data)
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H230
2
nd
motor constant R1
(Autotuning data)
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H031
1
s t
motor constant R 2
(Autotuning data)
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H231
2
nd
motor constant R 2
(Autotuning data)
0.000-9.999/10.00-65.53(ohm)
Set on
forwarding
H032
1
s t
motor constant L
(Autotuning data)
0.00-99.99/100.0-655.3( mH)
Set on
forwarding
H232
2
nd
motor constant L
(Autotuning data)
0.00-99.99/100.0-655.3( mH)
Set on
forwarding
H033
1
s t
motor constant I
0
(Autotuning data)
0.00-99.99/100.0-655.3(A)
Set on
forwarding
H233
2
nd
motor constant I
0
(Autotuning data)
0.00-99.99/100.0-655.3(A)
Set on
forwarding
H034
1
s t
motor constant J
0.001-9.999/10.00-99.99/100.0-9999.( kgm
2
)
Set on
forwarding
H234
2
nd
motor constant J
0.001-9.999/10.00-99.99/100.0-9999.( kgm
2
)
Set on
forwarding
H050
1
s t
PI-control proportion gain
setting
0.00-99.99/100.0-999.9/1000.(%)
100.0
H250
2
nd
PI-control proportion gain
setting
0.00-99.99/100.0-999.9/1000.(%)
100.0
H051
1
s t
PI-control integration gain
setting
0.00-99.99/100.0-999.9/1000.(%)
100.0
H251
2
nd
PI-control integration gain
setting
0.00-99.99/100.0-999.9/1000.(%)
100.0
H052
1
s t
P-control proportion gain
setting
0.01-10.00
1.00
H252
2
nd
P-control proportion gain
setting
0.01-10.00
1.00
H060
1
s t
0Hz-SLV limiter setting
0.-100.(%)
100.
H260
2
nd
0Hz-SLV limiter setting
0.-100.(%)
100.
H070
PI-control proportion gain for
switching
0.00-99.99/100.0-999.9/1000.(%)
100.0
H071
PI-control integration gain for
switching
0.00-99.99/100.0-999.9/1000.(%)
100.0
H072
P-control proportion gain for
switching
0.00-10.00
1.00
(Note) < > indicate the setting range of 75 to 150kW
The others
Содержание SJ300 Series
Страница 39: ...Internal block diagram ...
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......