ENGLISH
Mark
Part name
Description
28
Auxiliary power
Power supply for ATW-RTU and central device
29
30(N)
Electrical Heater DHW Output
If DHW tank contains an electric heater, the air to water heat pump can activate it if the heat
pump cannot achieve the required DHW temperature by itself.
31(L)
32
Output 9
33(L)
L common
Power supply for valve accessories
34(N)
N common
Neutral terminal common for outputs 1 , 2 and 9.
35(L)
Output 1 (3-way valve for swimming
pool) (*)
The air to water heat pump can be use to heat swimming pool. This output will be ON when
swimming pool is activated.
36(L)
Output 2 (Water pump 3 (WP3)) (*)
When there is a hydraulic separator or buffer tank, additional water pump (WP3) is needed.
37
Output 3 (Auxiliary boiler or electric
heater) (*)
The boiler can be used to alternate with the heat pump when the heat pump cannot achieve the
required temperature by itself.
A water electric heater (as accessory) can be used to provide the additional heating required on
the coldest days of the year.
38
39
Output 4 (Solar) (*)
Output for solar combination with Domestic Hot Water Tank.
40
?
N O T E
(*): Inputs and outputs explained in the table are the factory-set options. By means of the unit controller, some other inputs and outputs functions can
be configured and used. Please, refer to the Service Manual for detailed information.
7.4.3.5 Input terminals (Default input functions)
Room thermostat communication cables
There are two different room thermostat types as accessory
Optional wireless intelligent room thermostat (TB2) ATW-RTU
Only for wireless room thermostat accessory: the receiver is connected to the polarity-free terminals1 and 2.
The Wireless room thermostat and the Intelligent receiver are already configured to communicate with each other. If the Wireless
room thermostat or the Intelligent receiver is replaced or an additional second temperature circuit thermostat is added, it is
necessary to rebind them as explained in the manual of the Wireless intelligent room thermostat.
The Intelligent receiver is connected to the indoor unit table board as shown in the next picture:
1
2
1
2
H-LINK
ATW-RTU
28
29
L
N
AUXILIARY POWER
(ATW-RTU)(CENTRAL
DEVICE)
Power supply: 230V AC 50Hz
PC-ARFH2E connection
In cases where another PC-ARFH2E must be connected as a second thermostat, the connections between PC-ARFH2E and the
indoor unit must be done in terminals 3 and 4, as it is shown in the next picture:
3
4
A
B
RCS H-LINK
(PC-ARFH2E)
OK
ELECTRICAL AND CONTROL SETTINGS
PMML0575 rev.2 - 03/2022
119