 The following phenomena do not indicate unit failure.

FrostWash Operation

Noise occurred

 

during 

FrostWash 

operation

FrostWash Operation

 

does not start

Within 60 minutes after the end of "

FrostWash

", "

FrostWash

" is not operated for 

product protection.

It is the sound that the internal machine is inflated and contracted by the 

temperature change and the fin of the heat exchanger is frozen and thawed

Repeat for 1 se

 

cond

 

on and 1 second off  for 10 seconds

Because "

FrostWash

" can not work when  operating the  "

FrostWash

" with remote 

controller.

The air conditioner is operating

Outside air temperature, room temperature and room humidity are not  

suitable for "

FrostWash

"

It has not been over 60 minutes since the end of  "

FrostWash

"

Repeat for 4 seconds on and 1 second off  for 15 seconds

 

Because 

FrostWash has not been done for a long time

.

Operate the remote controller to operate  "

FrostWash

".

·

·

·

It does not wash  when outside  temperature is less than about 1 degrees Celsius or  

more than 43 degrees Celsius. 

It does not wash when the humidity in the room is about 30% or less or about 70% or 

more. 

When "

FrostWash

" is done by operating a remote controller,   it does not wash  

when the room temperature is less than about 10 degrees Celsius or more than 

about

 

32 degrees Celsius.

-9-

         

(

Clean Function 

Lamp) blinks

- 9 -

ENGLIS

H

<Operation start>

The unit is preparing to blow warm air. Please wait.

<In operation>

The outdoor unit is defrosting. Please wait.

During heating, the operation

indicator blinks and air blow stops

Hissing or fizzy sounds

Refrigerant flow noise in the pipe or valve sound generated when flow rate is

adjusted.

Squeaking noise

Noise generated when the unit expands or contracts due to temperature changes.

Rustling noise

Noise generated with the indoor unit fan’s rpm changing such as operation start

times.

Clicking noise

Noise of the motorized valve when the unit is switched on.

Noise of the ventilation fan sucking in air present in the drain hose and blowing out

dehumidifying water that had accumulated in the condensed water collector. For

details, consult your sales agent.

Perking noise

Changing operation noise

Operation noise changes due to power variations according to room temperature

changes.

Mist emission

Mist is generated as the air within the room is suddenly cooled by conditioned air.

Steam emitted from the outdoor unit

Water generated during defrosting operation evaporates and steam is emitted.

Odors

Caused as the smells and particles of smoke, food, cosmetics, etc. present in room

air become attached the unit and blown off into the room again.

The outdoor unit continues to operate

even if operation is stopped.

Defrosting is underway (as the heating operation is stopped, the microcomputer

checks frost accumulated in the outdoor unit and instructs the unit to perform

automatic defrosting if necessary).
Shows preheating or defrosting operation is underway.

As the protective circuit or preheat sensor operates when unit operation is stopped

during preheating and then restarted, or when operation mode is switched from cooling

to heating, the lamp continues to blink.

The OPERATION lamp is flashing.

Does not reach the temperature

setting

Actual  room  temperature  may  deviate  slightly  from  the  remote  controller's

temperature setting depending on the number of people in the room, indoor or

outdoor conditions.

Содержание RAK-DJ25PHAT

Страница 1: ...es art medicine or such Instruction manual Page 1 10 To obtain the best performance and ensure years of trouble free use please read this instruction manual completely MODEL RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT R32 RC AGU1EA0G 0025041B 1 ENGLISH Split Type Air Conditioner Indoor Unit ...

Страница 2: ...f improperly PRECAUTIONS DURING SHIFTING OR MAINTENANCE OFF PROHIBITION Make sure that a single phase 220V 240V power source is used The use of other power sources may cause electrical components to overheat and lead to fire Please keep this manual after reading Make sure to connect earth line Indicates the instructions that must be followed This sign in the figure indicates prohibition Do not ins...

Страница 3: ...omatically for a long period of time water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be a...

Страница 4: ...fer page 6 Front panel Refer page 7 Indoor unit indicators Light indicator showing the operating condition Refer page 5 Horizontal deflector Vertical deflector Air Outlet Remote controller Send out operation signal to the indoor unit So as to operate the whole unit Operation mode Cooling Heating Min Max Min Max Indoor temperature Dry bulb C Dry bulb C 21 32 20 27 Wet bulb C Wet bulb C 15 23 12 19 ...

Страница 5: ...g speed becomes slower when the air purifying filters are used The air purifying filters are not washable It is recommended to use vacuum to clean It can be used for 1 year When you want to renew it please ask your sales agent Operation Lamp Yellow This lamp lights during operation The Operation Lamp flashes in the following cases during heating 1 2 Air Filter Filter Frame C case Air purifying fil...

Страница 6: ...d close it Do not wash with hot water at more than 40 C The filter may shrink Do not wash with pressing hard on the filter bending too much or using a brush The filter may break When washing it shake off moisture completely and dry it in the shade do not expose it directly to the sun The filter may shrink Don t operate the unit without filter Fault may occur if you continue guide guide insert the ...

Страница 7: ...ng Off Period Run the unit by setting the operation mode to FAN and the fan speed to Super High for about half a day on a fine day and dry the whole of the unit Switch off the power plug or turn off the circuit breaker BENZINE THINNER A C I D Air Blow Method of removing the front panel Be sure to hold the front panel with both hands to detach and attach it Removing the Front Panel Attaching the Fr...

Страница 8: ... Inspection PLEASE CHECK THE FOLLOWING POINTS EVERY EITHER HALFYEARLY ORYEARLY CONTACT YOUR SALES AGENT SHOULD YOU NEED ANY HELP 1 2 WARNING WARNING Check to see if the unit s earth line has been con nected correctly If the earth line is disconnected or faulty unit failure or electric shock hazard may result Check to see if the mounting frame has rusted ex cessively or if the outdoor unit has tilt...

Страница 9: ...ve sound generated when flow rate is adjusted Squeaking noise Noise generated when the unit expands or contracts due to temperature changes Rustling noise Noise generated with the indoor unit fan s rpm changing such as operation start times Clicking noise Noise of the motorized valve when the unit is switched on Noise of the ventilation fan sucking in air present in the drain hose and blowing out ...

Страница 10: ...e fan casing which is cooled and then gradually warmed as operation stops s The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So please clean the air filter and the evaporator regularly to reduce the odor s Please contact your sales agent immediately if the air conditioner still fails to operate nor...

Отзывы: