Maintenance

1.

Air Filter

Please clean the filter once about every two weeks. By doing so, 

energy costs

 are saved. In 

case the air filter is full of dust, the air flow will decrease and the cooling capacity will be reduced. 
Further, noise may occur. Be sure to clean the filter following the procedure below.

PROCEDURE

1

Open the front panel carefully and remove the filter.

2

Vacuum dust from the air filter using vacuum cleaner.
If there is too much dust,  wash the filter with a detergent
and rinse it thoroughly. After that, dry it in the shade.

3

s

  Set the filter with "FRONT" mark facing front, and 

 slot them into the original state with putting the filter 

    on the guide. and insert the hook to the hole.

s

 

After attaching the filters, push the front panel at
three arrow portions as shown in figure and close
it.

Do not wash with hot water at more than 40°C. The filter may shrink.

Do not wash with pressing hard on the filter, bending too much or using a brush. The filter may 

break.

When washing it, shake off moisture completely and dry it in the shade; do not expose it directly

to the sun. The filter may shrink.

Don't operate the unit without filter. Fault may occur if you continue.

guide

guide

insert the hook to the hole

- 6 -

 CAUTION

 CAUTION

Ensure unit and power supply is switched off before cleaning.                    
Avoid touching any metal parts directly and do not use wet hands.
Cleaning shall be carried out by competent person and able to follow below instruction.

Air purifying filter to be inspected at least once a month or sooner depending on the usage 
of the air conditioner. If noticeable loading occurs on the unit, please clean it to avoid 
deterioration of its deodorizing function. For better performance, it is advisable to replace 
it every 1 year (subject to usage and application requirements).

NOTE:

Содержание RAK-DJ25PHAT

Страница 1: ...es art medicine or such Instruction manual Page 1 10 To obtain the best performance and ensure years of trouble free use please read this instruction manual completely MODEL RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT R32 RC AGU1EA0G 0025041B 1 ENGLISH Split Type Air Conditioner Indoor Unit ...

Страница 2: ...f improperly PRECAUTIONS DURING SHIFTING OR MAINTENANCE OFF PROHIBITION Make sure that a single phase 220V 240V power source is used The use of other power sources may cause electrical components to overheat and lead to fire Please keep this manual after reading Make sure to connect earth line Indicates the instructions that must be followed This sign in the figure indicates prohibition Do not ins...

Страница 3: ...omatically for a long period of time water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be a...

Страница 4: ...fer page 6 Front panel Refer page 7 Indoor unit indicators Light indicator showing the operating condition Refer page 5 Horizontal deflector Vertical deflector Air Outlet Remote controller Send out operation signal to the indoor unit So as to operate the whole unit Operation mode Cooling Heating Min Max Min Max Indoor temperature Dry bulb C Dry bulb C 21 32 20 27 Wet bulb C Wet bulb C 15 23 12 19 ...

Страница 5: ...g speed becomes slower when the air purifying filters are used The air purifying filters are not washable It is recommended to use vacuum to clean It can be used for 1 year When you want to renew it please ask your sales agent Operation Lamp Yellow This lamp lights during operation The Operation Lamp flashes in the following cases during heating 1 2 Air Filter Filter Frame C case Air purifying fil...

Страница 6: ...d close it Do not wash with hot water at more than 40 C The filter may shrink Do not wash with pressing hard on the filter bending too much or using a brush The filter may break When washing it shake off moisture completely and dry it in the shade do not expose it directly to the sun The filter may shrink Don t operate the unit without filter Fault may occur if you continue guide guide insert the ...

Страница 7: ...ng Off Period Run the unit by setting the operation mode to FAN and the fan speed to Super High for about half a day on a fine day and dry the whole of the unit Switch off the power plug or turn off the circuit breaker BENZINE THINNER A C I D Air Blow Method of removing the front panel Be sure to hold the front panel with both hands to detach and attach it Removing the Front Panel Attaching the Fr...

Страница 8: ... Inspection PLEASE CHECK THE FOLLOWING POINTS EVERY EITHER HALFYEARLY ORYEARLY CONTACT YOUR SALES AGENT SHOULD YOU NEED ANY HELP 1 2 WARNING WARNING Check to see if the unit s earth line has been con nected correctly If the earth line is disconnected or faulty unit failure or electric shock hazard may result Check to see if the mounting frame has rusted ex cessively or if the outdoor unit has tilt...

Страница 9: ...ve sound generated when flow rate is adjusted Squeaking noise Noise generated when the unit expands or contracts due to temperature changes Rustling noise Noise generated with the indoor unit fan s rpm changing such as operation start times Clicking noise Noise of the motorized valve when the unit is switched on Noise of the ventilation fan sucking in air present in the drain hose and blowing out ...

Страница 10: ...e fan casing which is cooled and then gradually warmed as operation stops s The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So please clean the air filter and the evaporator regularly to reduce the odor s Please contact your sales agent immediately if the air conditioner still fails to operate nor...

Отзывы: