2.

Cleaning of Front Panel

Remove the front panel and wash with clean water.

Wash it with a soft sponge.

After using neutral detergent, wash thoroughly with

clean water.
When front panel is not removed, wipe it with a soft

dry cloth. Wipe the remote controller thoroughly with

a soft dry cloth.
Wipe the water thoroughly.

If water remains at indicators or signal receiver of

indoor unit, it causes trouble.

 CAUTION

Do not splash or direct water to the body of the unit when cleaning it as

this may cause short circuit.

Never use hot water (above 40°C), benzine, gasoline, acid, thinner or a

brush, because they will damage the plastic surface and the coating.

3.

Maintenance at Beginning of Long Off Period

Run the unit by  setting  the operation mode to

 (FAN) and the fan speed to 

Super High

 for about half 

a day

 

on a fine day, and dry the whole of the unit.

Switch off the power plug or turn off the circuit breaker.

BENZINE

THINNER

A
C

I

D

Air

Blow

Method of removing the front panel.

Be sure to hold the front panel with both hands to

detach and attach it.

Removing the Front Panel

Attaching the Front Panel

  Push the end of the right-side arm outward to release 

the tab.

  Move the left-side arm outward to release the left tab, 

and then pull the panel towards you.

  Insert the shaft of the left arm along the step on the 

  unit into the hole. 
  Securely insert the shaft of the right arm along the 

  step on the unit into the hole. 

Make

 

sure

 

that

 

the

 

front

 

panel

 

is securely attached,

  and then close the front panel. 

1.

2.

1.

2.

3.

Arm

2

1

Move

Arm

Shaft

Push

Insert

Insert

Step

1

2

- 7 -

ENGLIS

H

Содержание RAK-DJ25PHAT

Страница 1: ...es art medicine or such Instruction manual Page 1 10 To obtain the best performance and ensure years of trouble free use please read this instruction manual completely MODEL RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT R32 RC AGU1EA0G 0025041B 1 ENGLISH Split Type Air Conditioner Indoor Unit ...

Страница 2: ...f improperly PRECAUTIONS DURING SHIFTING OR MAINTENANCE OFF PROHIBITION Make sure that a single phase 220V 240V power source is used The use of other power sources may cause electrical components to overheat and lead to fire Please keep this manual after reading Make sure to connect earth line Indicates the instructions that must be followed This sign in the figure indicates prohibition Do not ins...

Страница 3: ...omatically for a long period of time water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be a...

Страница 4: ...fer page 6 Front panel Refer page 7 Indoor unit indicators Light indicator showing the operating condition Refer page 5 Horizontal deflector Vertical deflector Air Outlet Remote controller Send out operation signal to the indoor unit So as to operate the whole unit Operation mode Cooling Heating Min Max Min Max Indoor temperature Dry bulb C Dry bulb C 21 32 20 27 Wet bulb C Wet bulb C 15 23 12 19 ...

Страница 5: ...g speed becomes slower when the air purifying filters are used The air purifying filters are not washable It is recommended to use vacuum to clean It can be used for 1 year When you want to renew it please ask your sales agent Operation Lamp Yellow This lamp lights during operation The Operation Lamp flashes in the following cases during heating 1 2 Air Filter Filter Frame C case Air purifying fil...

Страница 6: ...d close it Do not wash with hot water at more than 40 C The filter may shrink Do not wash with pressing hard on the filter bending too much or using a brush The filter may break When washing it shake off moisture completely and dry it in the shade do not expose it directly to the sun The filter may shrink Don t operate the unit without filter Fault may occur if you continue guide guide insert the ...

Страница 7: ...ng Off Period Run the unit by setting the operation mode to FAN and the fan speed to Super High for about half a day on a fine day and dry the whole of the unit Switch off the power plug or turn off the circuit breaker BENZINE THINNER A C I D Air Blow Method of removing the front panel Be sure to hold the front panel with both hands to detach and attach it Removing the Front Panel Attaching the Fr...

Страница 8: ... Inspection PLEASE CHECK THE FOLLOWING POINTS EVERY EITHER HALFYEARLY ORYEARLY CONTACT YOUR SALES AGENT SHOULD YOU NEED ANY HELP 1 2 WARNING WARNING Check to see if the unit s earth line has been con nected correctly If the earth line is disconnected or faulty unit failure or electric shock hazard may result Check to see if the mounting frame has rusted ex cessively or if the outdoor unit has tilt...

Страница 9: ...ve sound generated when flow rate is adjusted Squeaking noise Noise generated when the unit expands or contracts due to temperature changes Rustling noise Noise generated with the indoor unit fan s rpm changing such as operation start times Clicking noise Noise of the motorized valve when the unit is switched on Noise of the ventilation fan sucking in air present in the drain hose and blowing out ...

Страница 10: ...e fan casing which is cooled and then gradually warmed as operation stops s The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So please clean the air filter and the evaporator regularly to reduce the odor s Please contact your sales agent immediately if the air conditioner still fails to operate nor...

Отзывы: