Pay special attention to signs of “

 Warning

” and “

 Caution

”. The “Warning” section contains matters which, if

not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result
in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.

The signs indicate the following meanings. (The following are examples of signs.)

WARNING

SAFETY PRECAUTION

  Do not reconstruct the unit.

Water leakage, fault, short circuit or fi re may occur if you reconstruct the unit by 
yourself.

  Please ask your sales agent or qualified technician for the installation of your unit. 

Water leakage, short circuit or fire may occur if you install the unit by yourself.

  Please use earth line.

Do not place the earth line near water or gas pipes, lightning-conductor, or the 
earth  line  of  telephone.  Improper  installation  of  earth  line  may  cause  electric 
shock or fire.

  Be sure to use the specif ied piping set for 

. Otherwise, this may result in 

broken copper pipes or faults.

  A circuit breaker should be installed depending on the mounting site of the unit. 

Without a circuit breaker, the danger of electric shock exists.

  Please ensure smooth fl ow of water when installing the drain hose.

PRECAUTIONS DURING INSTALLATION

PROHIBITION

CONNECT EARTH LINE

PROHIBITION

WARNING

CAUTION

  Please  contact  your  agent  for  maintenance.  Improper  self  maintenance  may  cause  electric 

shock and fi re.

  Please contact your agent if you need to remove and reinstall the unit. Electric shock or fi re 

may occur if you remove and reinstall the unit yourself improperly.

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

“OFF”

PROHIBITION

  Make sure that a single phase           

220V-

240

V

 

         power source is used.

   

The use of other power sources may cause electrical components to overheat 

  

and lead to fi re.

• Please keep this manual after reading.

Make sure to connect earth line.

Indicates the instructions that must be followed.

This sign in the figure indicates prohibition.

Do not install the unit near a location where there is flammable gas.

The outdoor unit may catch fire if flammable gas leaks around it. 

Should abnormal situation arise (like burning smell), please stop operating the

unit and turn off the circuit breaker. Contact your 

fire may occur if you continue to operate the unit under abnormal situation.

agent. Fault, short circuit or 

PRECAUTIONS DURING OPERATION

WARNING

 Do not use any conductor as fuse wire, this could cause fatal accident.

  During  thunder  storm,  disconnect  the  plug  top  and  turn  off  the  circuit 

breaker.

  Do  not  put  objects  like  thin  rods  into  the  panel  of  blower  and  suction  side 

because the high-speed fan inside may cause danger.

 Spray cans and other combustibles should not be located within a meter of the 

air outlets of both indoor and outdoor units. 

As a spray can’s internal pressure can be increased by hot air, a rupture may result.

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

“OFF”

 Avoid an extended period of direct airflow for your health.

• Do not use refrigerant other than the one indicated on the outdoor unit (R32) when installing,

Using other refrigerants may cause trouble or damage to the unit, and personal injury.

moving or repairing.

. Otherwise, this may result in 

R32

Please read the “Safety Precaution” carefully before operating 

the unit to ensure correct usage of the unit.

This appliance is filled with R32.

- 2 -

Содержание RAK-DJ25PHAT

Страница 1: ...es art medicine or such Instruction manual Page 1 10 To obtain the best performance and ensure years of trouble free use please read this instruction manual completely MODEL RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT RAK DJ25PHAT RAK DJ35PHAT RAK DJ50PHAT R32 RC AGU1EA0G 0025041B 1 ENGLISH Split Type Air Conditioner Indoor Unit ...

Страница 2: ...f improperly PRECAUTIONS DURING SHIFTING OR MAINTENANCE OFF PROHIBITION Make sure that a single phase 220V 240V power source is used The use of other power sources may cause electrical components to overheat and lead to fire Please keep this manual after reading Make sure to connect earth line Indicates the instructions that must be followed This sign in the figure indicates prohibition Do not ins...

Страница 3: ...omatically for a long period of time water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be a...

Страница 4: ...fer page 6 Front panel Refer page 7 Indoor unit indicators Light indicator showing the operating condition Refer page 5 Horizontal deflector Vertical deflector Air Outlet Remote controller Send out operation signal to the indoor unit So as to operate the whole unit Operation mode Cooling Heating Min Max Min Max Indoor temperature Dry bulb C Dry bulb C 21 32 20 27 Wet bulb C Wet bulb C 15 23 12 19 ...

Страница 5: ...g speed becomes slower when the air purifying filters are used The air purifying filters are not washable It is recommended to use vacuum to clean It can be used for 1 year When you want to renew it please ask your sales agent Operation Lamp Yellow This lamp lights during operation The Operation Lamp flashes in the following cases during heating 1 2 Air Filter Filter Frame C case Air purifying fil...

Страница 6: ...d close it Do not wash with hot water at more than 40 C The filter may shrink Do not wash with pressing hard on the filter bending too much or using a brush The filter may break When washing it shake off moisture completely and dry it in the shade do not expose it directly to the sun The filter may shrink Don t operate the unit without filter Fault may occur if you continue guide guide insert the ...

Страница 7: ...ng Off Period Run the unit by setting the operation mode to FAN and the fan speed to Super High for about half a day on a fine day and dry the whole of the unit Switch off the power plug or turn off the circuit breaker BENZINE THINNER A C I D Air Blow Method of removing the front panel Be sure to hold the front panel with both hands to detach and attach it Removing the Front Panel Attaching the Fr...

Страница 8: ... Inspection PLEASE CHECK THE FOLLOWING POINTS EVERY EITHER HALFYEARLY ORYEARLY CONTACT YOUR SALES AGENT SHOULD YOU NEED ANY HELP 1 2 WARNING WARNING Check to see if the unit s earth line has been con nected correctly If the earth line is disconnected or faulty unit failure or electric shock hazard may result Check to see if the mounting frame has rusted ex cessively or if the outdoor unit has tilt...

Страница 9: ...ve sound generated when flow rate is adjusted Squeaking noise Noise generated when the unit expands or contracts due to temperature changes Rustling noise Noise generated with the indoor unit fan s rpm changing such as operation start times Clicking noise Noise of the motorized valve when the unit is switched on Noise of the ventilation fan sucking in air present in the drain hose and blowing out ...

Страница 10: ...e fan casing which is cooled and then gradually warmed as operation stops s The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So please clean the air filter and the evaporator regularly to reduce the odor s Please contact your sales agent immediately if the air conditioner still fails to operate nor...