– 55 –
Med
Set to 7 hours
0.5hr
7hr
See basic operation
Lo
Silent Sleep
Med
Hi
Indoor fan
Timer lamp
Operation lamp
Sleep key
Outdoor fan
Compressor speed
Compressor speed
Lo
Cooling Sleep Operation
Notes:
(1)
The sleep operation starts when the sleep key is pressed.
(2)
When the sleep key is set, the maximum compressor speed is limited to CBEMAX, and the indoor
fan is set to “Sleep Silent” (FCSOY).
(3)
If the operation mode is changed during sleep operation, the set temperature is cleared, and shift
starts from the point when switching is made.
(4)
The indoor fan speed does not change even when the fan speed mode is changed.
(5)
When operation is stopped during sleep operation, the set temperature when stopped, as well as
the time, continue to be counted.
(6)
If the set time is changed during sleep operation, all data including set temperature, time, etc. is
cleared and restarted.
(7)
If sleep operation is canceled by the cancel key or sleep key, all data is cleared.
(8)
The indoor fan is stopped while the thermo is OFF during sleep operation.
(9)
There is no preset temperature shift due to time elapse.
1min.
C M I N H I
T E I O N
T E I O F
Med
Med
15sec.
3 minutes Balance period
See basic operation
Indoor heat exchange temperature
Hi
Med
Lo
Silent Sleep
Indoor fan
Cooling defrost signal
Outdoor fan
Compressor speed
Reversing valve
(Heating "ON" mode)
Cooling Defrost