– 143 –
TROUBLE SHOOTING WHEN THE TIMER LAMP BLINKS
MODEL RAS-25WX8, RAS-35WX8
LJ
Cautions
Lj
(1) If the interface circuit is faulty when power is supplied, the self-diagnosis display will not be displayed.
(2) If the indoor unit does not operate at all, check if the connecting cable is connected to the outdoor unit.
(3) To check operation again when the timer is blinking, you can use the remote control for operation
(except for mode marked
Ć
).
Ć
1
Once
2 sec.
2 Times
3 Times
9 Times
13 Times
2 sec.
2 sec.
2 sec.
2 sec.
IC401 defective
Reversing valve defective
Forced operation of outdoor unit
Indoor/Outdoor interface defective
e
v
i
t
c
e
f
e
d
n
i
a
M
e
d
o
m
g
n
i
k
n
il
b
p
m
a
L
Indoor sensor defective
4 Times
2 sec.
Outdoor defective indication
10 Times
2 sec.
Abnormal rotating numbers
of DC fan motor (Upper)
)
(
Lights for 0.35 sec. at
interval of 0.35 sec.
When the timer lamp on the display section of the indoor unit blinks, refer to the following table.