7-13
7.2.10 DC Power Supply Fan Fault
Yes
Connect the connector.
DC Power Supply Fan
Fault
Is the multiple power supply fan
running?
No
Is the EZJ93 CN9 connector or
multiple power supply CN4
connector disconnected?
Yes
Replace the multiple power supply.
No
END
Is the problem fixed?
No
Yes
Replace the EZJ93 board.