![Hitachi PH Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/hitachi/ph/ph_instruction-manual_143796047.webp)
1-36
●
Connection of signals
●
The printing scan count maximum value is dependent on the printed character width
and conveyor maximum speed and calculated using the following equation.
Substitute the nozzle diameter suited for the model you are using for item d.
Printing scan count maximum value[kHz]
=conveyor maximum speed[m/min]×
1
60
horizontal dot count-1
character width[mm]-d[mm]
×
……(Equation 1)
nozzle diameter
d
65µm
0.3
●
Using Equation 2, check whether the printing scan count maximum value
determined by Equation 1 can be followed by the IJ printer printing speed.
kHz] >
Excitation frequency(f)
(Vertical dot count + character width s 1) x (ink drop use percentage)
printing scan count maximum value[kHz]……(Equation 2)
●
The excitation frequency (f) value varies with the ink type employed.
Ink type
Excitation frequency
65
μ
m Nozzle Machine
JP-K26
68.9kHz
JP-K27
68.9kHz
JP-R27
68.9kHz
JP-G27
68.9kHz
JP-K28
68.9kHz
JP-K33
74.0kHz
JP-K60
68.9kHz
JP-K61
68.9kHz
JP-K62
68.9kHz
JP-F63
68.9kHz
JP-T64
68.9kHz
JP-K65
68.9kHz
JP-K67
68.9kHz
JP-K68
68.9kHz
JP-K69
68.9kHz
JP-K70
68.9kHz
JP-T71
68.9kHz
JP-K72
68.9kHz
JP-T75
68.9kHz
JP-R76
68.9kHz
JP-K77
68.9kHz
JP-E78
68.9kHz
JP-F80
68.9kHz
JP-K81
68.9kHz
JP-B82
68.9kHz
JP-K83
68.9kHz
JP-K84
68.9kHz
JP-B85
68.9kHz
JP-K86
68.9kHz
JP-K87
68.9kHz
JP-K88
68.9kHz
JP-Y91
68.9kHz
JP-F92
68.9kHz
JP-Y94
68.9kHz
JP-B95
68.9kHz
JP-F97
74.0kHz
JP-K101
68.9kHz
JP-K106
68.9kHz