Performing setup so as to restrict the print data change function
Choose Maintenance from the menu.
1
The "Maintenance menu" screen then opens.
Press Password protection .
The "Password protection" screen then opens.
2
It is presumed that
"CZB05" is set as the
password.
Operations for
modifying the setting
contents
(See Section 2.1.3,
Operations for
modifying the setting
contents. )
Shut
down
Manual
Back
Environment setup
menu
Maintenance menu
Status: Ready
Operation
management
Test print
Excitation V update
(Nozzle test)
View alarm
history
Circulation control
View software
version
Comm. monitor
Password
protection
HOME
Limitation
change
Password protection
Status: Ready
Back
Password
When the password entry is accepted, you can change the
password protection setup.
Access
Access
Access
Access
Access
Access
Press C , Z , B , 0 , and 5 in sequence.
The password is then entered. The entered password is indicated by a string of
marks.
4
*
Press Enter password .
The cursor will move to the "Edit message" field.
The "Edit message", "Select message", "Save message", "Print specifications",
"Print format" and "Maintenance" can be input.
5
[ ]
Password protection
Status: Ready
Password
When the password entry is accepted, you can change the
password protection setup.
****
Press 1 .
The use of "Edit message" will be restricted.
6
Password [ ]
[ ] (0 : 1:protect)
Select message
[ 0 ] (0 : 1:protect)
Save message
[ 0 ] (0 : 1:protect)
Print specifications
[ 0 ] (0 : 1:protect)
Print format
[ 0 ] (0 : 1:protect)
Maintenance
[ 0 ] (0 : 1:protect)
Limitation
change
Password protection
Status: Ready
Back
When the password entry is accepted, you can change the
password protection setup.
Access
Access
Access
Access
Access
Access
Edit message
0
Press Back .
You are then returned to the "Maintenance menu" screen. The function you
restricted is now unexecutable.
●
To restrict other items, press item as needed to place the cursor in the target
field and then press 1 .
7
Cursor will move to the
line you touched.
Selected item on the
cursor-positioned line
can be changed by
touching.
Menu
Maintenace
Auxiliary
function
Operation
management
Show fault
/Warning
Environment
setup menu
Com=0
Com=0
Press Limitation change .
3
When HOME is
pressed, the system
returns to the print
description screen.
Содержание PH
Страница 274: ... Outside Dimensions 13 1 13 Schematic Diagrams 13 1 Outside Dimensions Fig 13 1 Model PH IJ printer outside dimensions ...
Страница 276: ... Electrical Connection Diagram 13 3 13 2 Electrical Connection Diagram Fig 13 3 Electrical connection diagram ...
Страница 277: ...13 4 Circulation System Diagram 13 3 Circulation System Diagram Fig 13 4 Circulation system diagram ...
Страница 288: ...2 K5253 1 ...