6 OPTIONAL FUNCTIONS
D A N G E R
Turn OFF the power source completely before performing the dip switch setting for receiver kit. If not, it may cause an elec
-
tric shock.
The following switches are on the receiver kit.
Dip switch (DSW1)
(Factory-setting)
Rear side of receiver kit
Cover
The dip switch (DSW1) is for the optional function selection. If the optional function selection is required, set the dip switch as follows.
Optional function
Dip switch setting (DSW1)
Details
1
2
3
4
5
6
Main/Sub Setting
O
X
X
X
X
X
Change main (OFF setting)/ sub (ON setting) remo
-
te control switches for 2 remote control system.
Identifying of Indoor Unit
X
O
X
X
X
X
It functions as B Mode (identifying of indoor unit) of
wireless remote control switch when it sets to “ON”.
Invalidity of Emergency Operation
X
X
X
O
X
X
The switches for emergency operation are invalid.
O: ON
X: OFF
C A U T I O N
• Pay attention to the following settings when the function for receiver kit is selected from the remote control switch or the centralized
controller.
• The cooling lower limit for setting temperature and the heating upper limit for setting temperature are not available. The setting is
available beyond the upper and lower limit for setting temperature from the wireless remote control switch.
• The optional function setting “Fixing of Setting Temperature” is not available. When the operation mode is
changed from the wire
-
less remote control switch, the indicated temperature on the remote control switch becomes set temperature.
10
PMML0314A rev.0 - 09/2013 - P5415315
Optional functions