INSTALLATION OF REMOTE CONTROL SWITCH <PC-2H2>

2

1.1.

 

BEFORE INSTALLATION

Check the contents and the number of the accessories in the
packing.

1 Remote Control

Switch, for Operation

Control

2 screws ø4x16L

For fixing the

Holding Bracket

onto the wall

1 Remote

Control Cable

(8 m) for

connection

1 Ring Core

and

1 Fixing Band

1.2.

 

INSTALLATION SPACE

In case of installing the controllers in vertical line, keep a
distance more than 10 mm between the controllers vertically.  If
the distance is insufficient, the front cover of the controller can
not open wide enough

Fig. 1 Installation Space

1.3.

 

INSTALLATION PROCEDURE

1. Insert the edge of the flat head screwdriver into the dent

parts at the bottom of the holding bracket, push and turn
the screwdriver and remove the controller from the holding
bracket as shown in the figure below.

Fig. 2  Installation Procedure

Fig. 3  Installation Procedure

2. Attach the controller to the holding bracket as follows.

A. In case of exposing Remote Control Cable.

É

Fix the holding bracket onto the wall as shown below

Fig. 4  Attach the controller

Ê

Make the hole for drawing out the cable

Select the position for drawing out the
cable among 3 positions marked with *
and make the knock-out hole by cutting off
with a cutter or so. Two sizes of the line for
the knock-out hole are prepared, and the
inner line is for the cable.

Fig. 5  Drawing out the cable

Controller

Dent
part

Holding
Bracket

Dent part

Holding
Bracket

Screwdriver

Holding Bracket

Dent part

Fix the holding bracket with
the mark "

UP" upward

Screw

(Accesory)

Dent
part

Bottom view

More Than 10 mm

Screwdriver

Содержание PC-2H2

Страница 1: ...onsultazioni Leia e compreenda este manual antes de operar este ar condicionado Guarde este manual para futura referencia De bor laese og forsta denne vejledning for de tager dette dlimaanlaeg i brug Opbervar vejledningen til senere reference Lees deze hadleiding aandachtig door alvorens de airconditioning in gebruik te nemen Läs och första denna manual innan Du sätter igang luftkonditioneraren Fö...

Страница 2: ......

Страница 3: ...run any cable for transmission and signal along the power line 220 240V 380 415V DO NOT run any cable for transmission and signal along other cables for transmission and signal If the cables are required to be run along keep a distance more than 30 cm between each cables or insert the cables for each transmission system into the metal conduit tube and ground one end of the conduit tube n Location ...

Страница 4: ...f the holding bracket push and turn the screwdriver and remove the controller from the holding bracket as shown in the figure below Fig 2 Installation Procedure Fig 3 Installation Procedure 2 Attach the controller to the holding bracket as follows A In case of exposing Remote Control Cable É Fix the holding bracket onto the wall as shown below Fig 4 Attach the controller Ê Make the hole for drawin...

Страница 5: ...nting work is finished Fig 10 Mounting procedures CAUTION Pay attention so that the cable may not be slack If the cable is slack as shown in the above figure the cable cord especially the naked part may be clamped at the hole and it may cause a faulty operation 1 4 WIRING SYSTEM FOR REMOTE CONTROL SWITCH PC 2H2 1 4 1 LENGTH OF WIRE CABLE FOR REMOTE CONTROL SWITCH Length of the standard wire cable ...

Страница 6: ...wires B After checking the color of the wires connect each wire of the same color by soldering C Insulate the soldered parts and the wires with insulation tape D The maximum total cable length of the remote control switch cable and the bridge cable s is 200 meters 0 3mm2 wire or 500 meters 0 75mm2 wire 3 Separate the cable more than approximately 30cm from any wires which are utilized for wires hi...

Страница 7: ... Bridge Cable 9 Contact of Connectors of Bridge Cable Ë Back to É after checking Ì Select TEST RUN MODE by depressing MODE Switch COOL OR HEAT Í Depress RUN STOP switch a The TEST RUN operation will be started The TEST RUN operation will be finished after 2 hours unit operation or by depressing the RUN STOP switch again b IF the unit do not start or the operation lamp on the remote control switch ...

Страница 8: ...pressor Heat Pump Twin 11 Thermistor Abnormality for inlet Air Temperature All Models 12 Thermistor Abnormality for outlet Air Temperature Heat Pump Twin 13 Thermistor Abnormality for Freezing Temperature All Models 20 Thermistor Abnormality for Compressor Top Temperature Heat Pump Twin 22 Thermistor Abnormality for Outdoor Air Temperature Heat Pump Twin 24 Thermistor Abnormality for Outdoor Evapo...

Страница 9: ...etting temperature is turned OFF b At the condition of the above item a press the TEMP switch or the TEMP switch of the remote control switch and the indoor unit for which the optional function is to be set can be changed NOTES The indoor unit can be selected among the indoor units connected to the remote control switch In case that both the indications of the address and the refrigerant cycle num...

Страница 10: ...0 01 Not Available Available b4 Change of Filter Cleaning Time 00 01 02 03 04 Standard 100 hours 1200 hours 2500 hours Not Indication b5 Fixing of Operation Mode 00 01 Not Available Available b6 Fixing of Setting Temperature 00 01 Not Available Available b7 Fixing of Operation as Exclusive Cooling Unit 00 01 Not Available Available b8 Automatic COOL HEAT 00 01 Not Available Available b9 Fixing of ...

Страница 11: ......

Страница 12: ...PMML0041B 12 01 Printed in Spain ...

Отзывы: