13 3
QM00971-1
Red
Regarding the indicator lamps
Regarding the indicator lamps (continued)
Indicator Status
Description
Firmware update is in progress.
For the details of the firmware update of the
projector, refer to our website.
PIN LOCK or TRANSITION DETECTOR
function is active.
See SECURITY menu > PIN LOCK or TANSITION
DETECTOR(
119, 120, 123
).
It is time to clean the air filter.
Turn the power off immediately, and clean or change
the air filter referring to the section
Cleaning and
replacing the air filter
. After cleaning or changing
the air filter, reset the filter time.
After the remedy, restart the projector.
The air filter is clogged or dirty.
(
124
)
Check and clean the air filter.
Make sure the power cord is not plugged in, then
allow the projector to cool sufficiently.
See the section "The interior portion has become
heated" (
134
).
NOTE
• The
FILTER
indicator might light up
in red when something blocks the intake vents
even though the air filter is clean.
• The
FILTER
indicator might light up
differently from other indicators or display
messages related to cleaning the air filter.
Follow the prompt that is displayed earlier.
(continued on next page)
Blinking In Green 1 time
Blinking In Red 1 time
Green
Red
Blinking In Red 2 ~ 3 times
Green
Orange
Blinking In Orange 1 time
Orange or Green