4-21
Setting analog input filter
Set the internal filter of the frequency setting signal of voltage or current
from the control terminals
It is important to first remove the source of the noise to the system.
When stable operation can not be achieved due to the effect of electrcal noise, set a larger value.
The response will be slower by setting a larger value. The limit of setting is about 2ms-60ms( set value : 1-
30)
Function code
Limit to set
Contents
A016
1.-30.
Can set with the 1 unit.
Output voltage gain
Regarding the voltage selected on A082 motor voltage selection as 100 %,
set the rate of the voltage which the inverter outputs for the voltage
selected.
Function code
Limit to set
Contents
A045
20.-100.
Unit:%
Chapter4 Explanation of function
A016: O, OI, O2 filter
Relation code
A045: Output voltage gain
A082: Motor voltage selection
Relation code
A45
Motor voltage
Selection (100%)
Maxi mum
frequency
Base
frequency