4-7
Function Mode
Code
Function name
Setting range
Initial data
-FE/-FU/-FR
Setting
on run
Change
mode on
run
Page
A061
1
s t
frequency upper limiter
0.00, 1
s t
frequency lower li miter-maximum frequency(Hz)
0.00
9
4-28
A261
2
n d
frequency upper li miter
0.00, 2
n d
frequency lower limiter-2
n d
setting maxi mum
frequency(Hz)
0.00
9
4-28
A062
1
s t
frequency lower li miter
0.00, start frequency-1
s t
frequency maximum limiter(Hz)
0.00
9
4-28
A262
2
n d
frequency lower li miter
0.00, start frequency-2
n d
frequency maximum li miter(Hz)
0.00
9
4-28
A063
Jump frequency1
0.00-99.99/100.0-400.0(Hz)
0.00
9
4-29
A064
Jump frequency W idth 1
0.00-10.00(Hz)
0.50
9
4-29
A065
Jump frequency2
0.00-99.99/100.0-400.0(Hz)
0.00
9
4-29
A066
Jump frequency W idth 2
0.00-10.00(Hz)
0.50
9
4-29
A067
Jump frequency3
0.00-99.99/100.0-400.0(Hz)
0.00
9
4-29
A068
Jump frequency W idth 3
0.00-10.00(Hz)
0.50
9
4-29
A069
Acceleration stop frequency
0.00-99.99/100.0-400.0(Hz)
0.00
9
4-29
A070
Acceleration stop ti me
0.00-60.0(s)
0.0
9
4-29
A071
PID selection
00(invalid)/01(valid)
00
9
4-30
A072
PID-P gain
0.2-5.0
1.0
9
9
4-30
A073
PID-I gain
0.0-3600.(s)
1.0
9
9
4-30
A074
PID-D gain
0.00-100.0(s)
0.00
9
9
4-30
A075
PID scale
0.01-99.99
1.00
9
4-30
A076
PID feedback selection
00(feedback : OI)/01(feedback : O)
00
9
4-30
A081
AVR selection
00(ON always)/01(OFF always)/02(OFF on decelerating)
00
-
4-17
A082
Motor voltage selection
200/215/220/230/240, 380/400/415/440/460/480
(230/400)
(230/460)
(200/400)
-
4-17
A085
Operation mode selection
00(normal operation)/01(energy-saving operation)
00
-
4-31
A086
Energy-saving response-
accuracy adjustment
0.0-100.0
50.0
9
9
4-31
A092
Acceleration ti me2
0.01-99.99/100.0-999.9/1000.-3600.(s)
15.00
9
9
4-32
A292
2
n d
acceleration time2
0.01-99.99/100.0-999.9/1000.-3600.(s)
15.00
9
9
4-32
A093
Deceleration time2
0.01-99.99/100.0-999.9/1000.-3600.(s)
15.00
9
9
4-32
A293
2
n d
deceleration ti me2
0.01-99.99/100.0-999.9/1000.-3600.(s)
15.00
9
9
4-32
A094
2
n d
stage adjustable selection
00(change with 2CH terminal)/01(change with setting)
00
-
4-32
A294
2
n d
stage adjustable
selection(2
n d
motor)
00(change with 2CH terminal)/01(change with setting)
00
-
4-32
A095
2
n d
acceleration frequency
0.00-99.99/100.0-400.0(Hz)
0.00
-
4-32
A295
2
n d
acceleration
frequency(2
n d
motor)
0.00-99.99/100.0-400.0(Hz)
0.00
-
4-32
A096
2
n d
deceleration frequency
0.00-99.99/100.0-400.0(Hz)
0.00
-
4-32
A296
2
n d
deceleration frequency
(2
n d
motor)
0.00-99.99/100.0-400.0(Hz)
0.00
-
4-32
A097
Acceleration pattern selection
00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)
00
-
4-33
A098
Deceleration pattern selection
00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)
00
-
4-33
A101
OI start
0.00-99.99/100.0-400.0(Hz)
0.00
9
4-20
A102
OI end
0.00-99.99/100.0-400.0(Hz)
0.00
9
4-20
A103
OI start rate
0.-100. (%)
20.
9
4-20
A104
OI end rate
0.-100. (%)
100.
9
4-20
A105
OI start selection
00(external start frequency)/01(0Hz)
01
9
4-20
A111
O2 start
-400.--100./-99.9-0.00-99.9/100.-400.(Hz)
0.00
9
4-20
A112
O2 end
-400.--100./-99.9-0.00-99.9/100.-400.(Hz)
0.00
9
4-20
A113
O2 start rate
-100. - 100. (%)
-100.
9
4-20
A114
O2 end rate
-100. - 100. (%)
100.
9
4-20
A131
Acceleration curve constant
01(small swelling)-10(large swelling)
02
9
4-33
A132
Deceleration curve constant
01(small swelling-10(large swelling)
02
9
4-33
b001
Retry selection
00(trip)/01(0Hz start)/02(start after equal frequency)/
03(trip after equaling frequency and deceleration stop)
00
9
4-34
b002
Allowable under-voltage
power failure ti me
0.3-1.0(s)
1.0
9
4-34
b003
Retry wait ti me
0.3-100.(s)
1.0
9
4-34
b004
Instantaneous power-
failure/under-voltage trip
during stop
00(invalid/01(valid)/
02(invalid during stop and deceleration by stop command)
00
9
4-34
b005
Instantaneous power-
failure/under-voltage
retry ti me selection
00(16 ti mes)/01(free)
00
9
4-34
b006
Open-phase selection
00(invalid)/01(valid)
00
9
4-36
b007
Frequency setting to match
0.00-99.99/100.0-400.0(Hz)
0.00
9
4-34
b012
Electronic thermal level
0.2*constant current-1.20*constant current(A)
Rated
Current of
inverter
9
4-36
b212
Electronic thermal level
(2
n d
motor)
0.2*constant current-1.20*constant current(A)
Rated
Current of
inverter
9
4-36
b013
Electronic thermal
characteristic selection
00/(reduced characteristic)01(constant torque characteristic)/
02(free setting)
01/01/00
9
4-36
b213
Electronic thermal
characteristic selection
(2
n d
motor)
00/(reduced characteristic)01(constant torque characteristic)/
02(free setting)
01/01/00
9
4-36
b015
Free electronic thermal
frequency 1
0.-400.(Hz)
0.
9
4-37
b016
Free electronic thermal
current 1
0.0-1000.(A)
0.0
9
4-37
b017
Free electronic thermal
frequency 2
0.-400.(Hz)
0.
9
4-37
b018
Free electronic thermal
current 2
0.0-1000. (A)
0.0
9
4-37
b019
Free electronic thermal
frequency 3
0.-400.(Hz)
0.
9
4-37
b020
Free electronic thermal
current 3
0.0-1000.(A)
0.0
9
4-37
Chapter 4 Explanation of function
U
p
p
e
r and l
o
w
e
r l
im
iter •
ju
m
p
fr
equ
e
ncy
PI
D c
o
n
tr
o
l
E
x
terna
l f
requ
ency
ad
ju
s
tm
e
n
t
AV
R
Op
erat
io
n m
o
de
•
a
d
justabl
e fun
c
ti
on
A
cce
l
De
c
e
l
Ins
tant
aneo
us pow
e
r
fa
il
u
re
re
s
tar
t
E
lect
ron
ic
t
herm
a
l
Содержание L300P-1100H
Страница 127: ...6 3 Chapter 6 Specification 6 2 Dimension L300P 110 150LF HF L300P 185 300LF HF ...
Страница 128: ...6 4 Chapter 6 Specification L300P 370LF HF L300P 450 550LF HF 750HF ...
Страница 129: ...6 5 Chapter 6 Specification L300P 750LF L300P 900H 1100H ...
Страница 130: ...6 6 Chapter 6 Specification L300P 1320HF ...