Travelstar 80GN Hard Disk Drive Specification
page 91
12.0 Command protocol
The commands are grouped into different classes according to the protocols followed for command execution. The
command classes with their associated protocols are defined below.
For all commands, the host must first check to see if BSY = 1, and should proceed no further unless and until
BSY = 0. For all commands, the host must also wait for RDY = 1 before proceeding.
A device must maintain either BSY = 1 or DRQ = 1 at all times until the command is completed. The INTRQ sig-
nal is used by the device to signal most, but not all, times when the BSY bit is changed from 1 to 0 during com-
mand execution.
A command shall only be interrupted with a hardware or software reset. The result of writing to the Command reg-
ister while BSY = 1 or DRQ = 1 is unpredictable and may result in data corruption. A command should only be
interrupted by a reset at times when the host thinks there may be a problem, such as a device that is no longer
responding.
Interrupts are cleared when the host reads the Status Register, issues a reset, or writes to the Command Register.
See Section 14.0, “Time-out values” on page 193 for the device time-out values.
12.1 Data In commands
The following are Data In commands:
•
Identify Device
•
Read Buffer
•
Read Long
•
Read Multiple
•
Read Multiple EXT
•
Read Sector(s)
•
Read Sector(s) EXT
•
S.M.A.R.T. Read Attribute Values
•
S.M.A.R.T. Read Attribute Thresholds
•
S.M.A.R.T. Read log sector
Execution includes the transfer of one or more 512 byte (> 512 bytes on Read Long) sectors of data from the device
to the host.
1. The host writes any required parameters to the Features, Sector Count, LBA, Cylinder, and Device Regis-
ters.
2. The host writes the command code to the Command Register.
3. For each sector (or block) of data to be transferred:
a. The device sets BSY = 1 and prepares for data transfer.
b. When a sector (or block) of data is available for transfer to the host, the device sets BSY = 0, sets
DRQ = 1, and interrupts the host.
c. In response to the interrupt, the host reads the Status Register.
d. The device clears the interrupt in response to the Status Register being read.
e. The host reads one sector (or block) of data via the Data Register.
f. The device sets DRQ = 0 after the sector (or block) has been transferred to the host.
Содержание IC25N020ATMR04
Страница 4: ......
Страница 10: ...15 2 SET FEATURES Commands Support Coverage 197 15 3 Changes from Travelstar 60GH and 40GN 198 ...
Страница 14: ......
Страница 20: ...Travelstar 80GN Hard Disk Drive Specification 10 ...
Страница 21: ...Travelstar 80GN Hard Disk Drive Specification 11 Part 1 Functional specification ...
Страница 22: ...Travelstar 80GN Hard Disk Drive Specification 12 ...
Страница 24: ...Travelstar 80GN Hard Disk Drive Specification 14 ...
Страница 34: ...Travelstar 80GN Hard Disk Drive Specification 24 ...
Страница 48: ...Travelstar 80GN Hard Disk Drive Specification 38 ...
Страница 67: ...Travelstar 80GN Hard Disk Drive Specification 57 Part 2 Interface specification ...
Страница 68: ...Travelstar 80GN Hard Disk Drive Specification 58 ...
Страница 70: ...Travelstar 80GN Hard Disk Drive Specification 60 ...
Страница 72: ...Travelstar 80GN Hard Disk Drive Specification 62 September 19 2003 10 28 am ...
Страница 100: ...Travelstar 80GN Hard Disk Drive Specification 90 ...
Страница 106: ...Travelstar 80GN Hard Disk Drive Specification page 96 ...
Страница 131: ...Travelstar 80GN Hard Disk Drive Specification 121 ...
Страница 202: ...Travelstar 80GN Hard Disk Drive Specification 192 ...
Страница 209: ...Travelstar 80GN Hard Disk Drive Specification 199 ...
Страница 210: ...Travelstar 80GN Hard Disk Drive Specification 200 ...
Страница 213: ...Hitachi Global Storage Technologies V Vibration 33 W Write Buffer 177 Write Cache function 87 Z Zone 16 ...